Machine learning analysis of integrated ABP and PPG signals towards early detection of coronary artery disease
Related Experiment Video
Updated: May 22, 2025

Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Amandeep Minhas1, Subhash Chandra Pal2, Karan Jain3
1Electrical Engineering Department, National Institute of Technology Durgapur, Durgapur, West Bengal, 713209, India. amanminhas01@gmail.com.
Insights
Early detection of Coronary Artery Disease (CAD) is possible using arterial blood pressure (ABP) and photoplethysmogram (PPG) signals. Neural networks achieved 90% accuracy, outperforming other methods for efficient CAD diagnosis.
Area of Science:
- Cardiology
- Biomedical Engineering
- Signal Processing
Background:
- Coronary Artery Disease (CAD) is a leading cause of mortality, often detected late when severe.
- Plaque buildup in coronary arteries gradually occludes blood flow to the heart.
- Early symptomatic detection of CAD is challenging, necessitating advanced diagnostic methods.
Purpose of the Study:
- To develop an efficient early-stage detection method for Coronary Artery Disease (CAD).
- To utilize arterial blood pressure (ABP) and photoplethysmogram (PPG) signals for CAD diagnosis.
- To improve timely clinical interventions for patients with CAD.
Main Methods:
- Collected ABP and PPG data from 73 CAD and 64 non-CAD subjects from the MIMIC-II database.
- Pre-processed signals using band-pass filters (2.5-16 Hz for ABP, 1.5-16 Hz for PPG).
- Extracted 19 features from each signal and employed classifiers like SVM, KNN, and Neural Networks (NN).
Main Results:
- Neural Networks (NN) demonstrated superior performance, achieving approximately 90% accuracy in CAD classification.
- The proposed method, using ABP and PPG signals, showed higher accuracy than existing state-of-the-art CAD detection techniques.
- Feature analysis identified key indicators for distinguishing between CAD and non-CAD subjects.
Conclusions:
- Early detection of CAD is feasible using a combination of ABP and PPG signals.
- The developed approach offers a promising, non-invasive method for efficient CAD diagnosis.
- The findings suggest that NN-based analysis of cardiovascular signals can significantly enhance CAD detection accuracy.
Abstract:
Every year, Coronary Artery Disease (CAD) claims lives of over a million people. CAD occurs when the coronary arteries, responsible for supplying oxygenated blood to the heart, get occluded due to plaque deposits on their inner walls. The most critical fact about this disease is that it develops gradually over the years and by the time symptomatic changes such as angina or shortness of breath appear, the disease has already become severe. The overall aim of the proposed work is to detect CAD efficiently in its early stage while utilizing (radial) arterial blood pressure (ABP) along with photoplethysmogram (PPG) signals so that necessary clinical measures may be taken timely. To achieve this objective, firstly, ABP and PPG data of 73 CAD and 64 non-CAD (not suffering from any cardiac condition) subjects have been collected from MIMIC-II waveform database with matched subset. Secondly, the collected data is pre-processed using band pass filters having bandwidths of 2.5 to 16 Hz and 1.5 to 16 Hz for ABP and PPG respectively. Thirdly, nineteen features have been extracted from each of the two signals; some of the key features include mean of pulse duration, mean of rising slope and ratio of low frequency to high frequency. Finally, extensive analysis on CAD and non-CAD classification is carried out on the basis of extracted features while employing state-of-the-art classifiers such as support vector machines (SVM), K-nearest neighbors (KNN) and neural networks(NN). The numerical experiments have led to the interpretation that neural network outperforms other classifiers, claiming an accuracy of about 90%. Moreover, accuracy of the proposed approach is found to be better than the state-of-the-art works reported in literature where one of or combinations of cardiovascular signals, namely, electrocardiogram (ECG), phonocardiogram (PCG) and photoplethysmogram (PPG) have been utilized for the CAD detection.
More Related Videos
08:22Author Spotlight: Advancing the Study of Brain-Heart Interplay with a Comprehensive EEGLAB Plugin for Multimodal Signal Analysis
Published on: April 26, 2024
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...