Background:
Indocyanine green (ICG) fluorescence has seen extensive application across medical and surgical fields, praised for its real-time navigation capabilities and low toxicity. Initially employed to assess liver function, ICG fluorescence is now integral to liver surgery, aiding in tumor detection, liver segmentation, and the visualization of bile leaks. This study reviews current protocols and ICG fluorescence applications in liver surgery, with a focus on optimizing timing and dosage based on clinical indications.
Methods:
Following PRISMA guidelines, we systematically reviewed the literature up to 27 January 2024, using PubMed and Medline to identify studies on ICG fluorescence used in liver surgery. A systematic review was performed to evaluate dosage and timing protocols for ICG administration.
Results:
Of 1093 initial articles, 140 studies, covering a total of 3739 patients, were included. The studies primarily addressed tumor detection (40%), liver segmentation (34.6%), and both (21.4%). The most common ICG fluorescence dose for tumor detection was 0.5 mg/kg, with administration occurring from days to weeks pre-surgery. Various near-infrared (NIR) camera systems were utilized, with the PINPOINT system most frequently cited. Tumor detection rates averaged 87.4%, with a 10.5% false-positive rate. Additional applications include the detection of bile leaks, lymph nodes, and vascular and biliary structures.
Conclusions:
ICG fluorescence imaging has emerged as a valuable tool in liver surgery, enhancing real-time navigation and improving clinical outcomes. Standardizing protocols could further enhance ICG fluorescence efficacy and reliability, benefitting patient care in hepatic surgeries.