Related Experiment Video
Updated: May 22, 2025

A Cross-Disciplinary and Multi-Modal Experimental Design for Studying Near-Real-Time Authentic Examination Experiences
Published on: September 4, 2019
Experimental Design (24) to Improve the Reaction Conditions of Non-Segmented Poly(ester-urethanes) (PEUs) Derived
Jaime Maldonado-Estudillo1, Rodrigo Navarro Crespo2, Ángel Marcos-Fernández2
1Departament of Chemistry, University of Guanajuato (UG), Noria Alta S/N, Guanajuato 36050, Mexico.
Abstract:
Aliphatic unsegmented polyurethanes (PUs) have garnered relatively limited attention in the literature, despite their valuable properties such as UV resistance and biocompatibility, making them suitable for biomedical applications. This study focuses on synthesizing poly(ester-urethanes) (PEUs) using 1,6-hexamethylene diisocyanate and the macrodiol α,ω-hydroxy telechelic poly(ε-caprolactone) (HOPCLOH). To optimize the synthesis, a statistical experimental design approach was employed, a methodology not commonly utilized in polymer science. The influence of reaction temperature, time, reagent concentrations, and solvent type on the resulting PEUs was investigated. Characterization techniques included FT-IR, 1H NMR, differential scanning calorimetry (DSC), gel permeation chromatography (GPC), optical microscopy, and mechanical testing. The results demonstrated that all factors significantly impacted the number-average molecular weight (Mn) as determined by GPC. Furthermore, the statistical design revealed crucial interaction effects between factors, such as a dependence between reaction time and temperature. For example, a fixed reaction time of 1 h, with the temperature varying from 50 °C to 61 °C, did not significantly alter Mn. Better reaction conditions yielded high Mn (average: 162,000 g/mol), desirable mechanical properties (elongation at break > 1000%), low levels of unreacted HOPCLOH in the PEU films (OH/ESTER response = 0.0008), and reduced crystallinity (ΔHm = 11 J/g) in the soft segment, as observed by DSC and optical microscopy. In contrast, suboptimal conditions resulted in low Mn, brittle materials with unmeasurable mechanical properties, high crystallinity, and significant amounts of residual HOPCLOH. The best experimental conditions were 61 °C, 0.176 molal, 8 h, and chloroform as the solvent (ε = 4.8).
More Related Videos
Related Concept Videos
Experimental Designs
Study Design in Statistics
Does aspirin reduce the risk of heart attacks? Is one brand of fertilizer more effective at growing roses than another? Is fatigue as dangerous to a driver as the influence of alcohol? Questions like these are answered using randomized experiments with proper...
What is an Experiment?
Factorial Design
Group Design
Crossover Experiments
Crossover designs are performed even with smaller sample sizes since the samples can act as their controls. These are better than simple randomized trials since patients are exposed to all the treatments.

