Demonstration of virtual imaging trial applications for optimization and education of dento-maxillofacial CBCT
Karen Merken1, Nicholas Marshall1, Johan Nuyts2
1KU Leuven, Department of Imaging and Pathology, Division of Medical Physics & Quality Assessment, Leuven, Belgium.
Background:
A number of studies have suggested that there is a need for improved understanding of dento-maxillofacial cone beam computed tomography (CBCT) technology, and to establish optimized imaging protocols. While several ex vivo/in vitro studies, along with a few in vivo studies, have addressed this topic, virtual imaging trials could form a powerful alternative but have not yet been introduced within the field of dento-maxillofacial imaging.
Purpose:
To introduce and illustrate the potential of utilizing a virtual imaging trial (VIT) platform for dento-maxillofacial CBCT imaging through a number of case studies.
Methods:
A framework developed in-house, simulating an existing CBCT scanner, and the necessary digital patient phantoms were prepared for the following potential studies: I) the impact of intracanal material type (Ni-Cr alloy, fiberglass, gutta-percha) and acquisition settings (tube current (mA), tube voltage (kVp)) on root fracture (RF) visibility; II) image artefact levels from candidate new restorative materials, such as graphene; III) the effect of patient rigid motion on image artifacts; IV) the effect of a metal artifact reduction algorithm on RF visibility in a tooth treated endodontically and restored with a metal post. In addition, features not available on the real system, including automatic exposure control and extended tube current and tube voltage ranges, were added to study the impact of these parameters. Patient dose levels were also quantified.
Results:
The generated images showed the influence of different restorative materials, dose levels, rigid motion, and image processing on the quality of the final images. Results of these simulated conditions were consistent with findings in the literature. Patient effective dose levels ranged between 22 and 138 for all simulated scenarios. Images were considered sufficiently realistic according to an experienced oral radiologist. Furthermore, the platform was able to simulate scenarios that are difficult or impossible to replicate physically in a controlled and repeatable way.
Conclusions:
A virtual imaging trial platform has the potential to improve the understanding and use of CBCT technology. Improved insight into system performance can lead to optimized imaging protocols, and help to reduce the large variation in system setup and performance currently seen in clinical practice in dento-maxillofacial CBCT imaging.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography