Concentration of Virus Particles from Environmental Water and Wastewater Samples Using Skimmed Milk Flocculation and Ultrafiltration
Published on: March 17, 2023
A comparative study on environmental surveillance of enterovirus: Using a two-phase separation method and a
Ling Fang1, Meizhong Chen1, Shuangli Zhu2
1Guangdong Provincial Center for Disease Control and Prevention, Guangdong Workstation for Emerging Infectious Disease Control and Prevention, Guangzhou 511430, China.
Abstract:
This study aimed to compare the sensitivity of two-phase separation and the filtration method using a mixed cellulose ester (MCE) membrane to detect enteroviruses in sewage samples. From December 2015 to July 2016, four domestic sewage samples (1 L/sample) were collected monthly from the Guangzhou Liede Sewage Treatment Plant, and each sewage sample was divided into two aliquots (500 mL). The sewage sample was concentrated using the two-phase separation and the filtration method using an MCE membrane, and the treated solutions were inoculated into cells for enterovirus isolation. Polymerase chain reaction amplification, VP1 sequencing, and enterovirus molecular typing were performed on the positive isolates. The detection rates of poliovirus (PV) and non-polio enterovirus (NPEV) obtained using the filtration method using an MCE membrane were higher than those using the two-phase separation method. McNemar's test showed that the detection rates of PV, NPEV, type 1 Sabin-like (SL1), type 2 Sabin-like (SL2), and type 3 Sabin-like (SL3) strain were not statistically significant (P > 0.05). In Guangdong Province, China, the detection rates for PV and NPEV were 53.13% and 62.50% (20/32), respectively. Twenty-seven PVs were isolated, three highly variable strains of the type 1 vaccine, with seven nucleotide substitutions in the VP1 region, compared with the type 1 Sabin strains. Eighty-seven strains of NPEV were isolated and nine serotypes were identified, among which coxsackievirus B3 (CVB3), echovirus 6(E6), and echovirus 11(E11) were the dominant strains. The filtration method using an MCE membrane is more sensitive than two-phase separation and can be used as a robust, sensitive, and cost-effective method to isolate enteroviruses from sewage.
More Related Videos
10:48EPA Method 1615. Measurement of Enterovirus and Norovirus Occurrence in Water by Culture and RT-qPCR. I. Collection of Virus Samples
Published on: March 28, 2015
11:09EPA Method 1615. Measurement of Enterovirus and Norovirus Occurrence in Water by Culture and RT-qPCR. II. Total Culturable Virus Assay
Published on: September 11, 2016