Related Experiment Video
Updated: May 22, 2025

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Comparable outcomes between cruciate-substituting and posterior-stabilized inserts in robotic total knee arthroplasty
Christos Koutserimpas1, Pietro Gregori1,2, Luca Andriollo1,3
1Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Hospices Civils de Lyon, Lyon, France.
Purpose:
Functional alignment (FA) has emerged as a personalized strategy in total knee arthroplasty (TKA) to optimize outcomes by accounting for patient-specific anatomical and soft tissue characteristics. Limited evidence exists on how polyethylene insert type, specifically cruciate-substituting (CS) versus posterior-stabilized (PS), impacts clinical outcomes and complications in this context.
Methods:
This retrospective comparative study included 329 patients who underwent robotic-assisted TKA with FA principles with a minimum 2-year follow-up. Patients were divided into two groups: CS or PS implants. CS inserts were selected for patients with an intact posterior cruciate ligament (PCL), while PS inserts were used in cases of PCL insufficiency or significant flexion contractures. Preoperative and post-operative outcomes, including Knee Society Scores (KSS), Forgotten Joint Scores (FJS), range of motion (ROM) and complications, were assessed. Implant survivorship was analyzed using the Kaplan-Meier method.
Results:
At a median follow-up of 36 months, no significant differences were observed between CS and PS groups in KSS (knee: p = 0.45; function: p = 0.4), FJS (p = 0.7) or ROM (median flexion: 130° in both groups, p = 0.52). Specific complications included intraoperative lateral condyle fractures in the PS group and femoral component revisions due to instability in the CS group. The overall complication rates and implant survivorship were comparable (p = 0.55 and p = 0.85, respectively).
Conclusion:
This study is the first to evaluate polyethylene insert type in FA and demonstrates that both CS and PS inserts provide comparable outcomes and safety profiles in robotic-assisted TKA. These findings underscore the importance of patient-specific implant selection, with further research needed to assess long-term results.
Level Of Evidence:
Level III.
More Related Videos
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022
07:33In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023