Related Experiment Video
Updated: May 22, 2025

Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
Evaluation of Different Surface Roughening Techniques on Clear Aligner Attachments Bonded to Monolithic Zirconia: In
Abdullah S Alhunayni1, Nehal F Albelasy2, Ahmad M Hafez2
1Department of Orthodontics, Faculty of Dentistry, Mansoura University, Mansoura, Egypt, Phone: +20 1142570764,
Aim:
The objective of this study is to assess the impact of three different surface etching techniques and two composite materials on surface roughness (Ra) and the shear bond strength (SBS) of clear aligner attachments bonded to monolithic zirconia (MZ).
Materials And Methods:
Sixty-six MZ disks were divided into three main groups (n = 22) according to the surface treatment method: group I: hydrofluoric acid (HFA) 9.5%, group II: 50 µm aluminum oxide (Al2O3) sandblasting, and group III: Er:Cr:YSGG laser. Each group was then subdivided into two subgroups according to the composite material (n = 11) used for bonding of the attachment, either packable composite Filtek Z350 or composite Filtek Z250. Clear aligner attachments were then bonded to the disks, and measurements of Ra and SBS were taken. Statistical analysis was carried out using the Kruskal-Wallis test and two-way analysis of variance.
Results:
The HFA groups showed the highest SBS (11.29 ± 2.83 MPa) and Ra (0.82 µm), while the laser groups exhibited the lowest SBS (8.29 ± 2.38 MPa) and Ra (0.634 µm). In Filtek Z350, there was a significant difference observed between the subgroups regarding SBS but not in Filtek Z250 subgroups.
Conclusion:
The 9.5% HFA provided the highest SBS value in comparison with Er:Cr:YSGG laser and sandblasting (p <0.05).
Clinical Significance:
This study has the potential to benefit both orthodontists and patients by providing insights into techniques that can improve the bond strength and longevity of clear aligner attachments to MZ. How to cite this article: Alhunayni AS, Albelasy NF, Hafez AM. Evaluation of Different Surface Roughening Techniques on Clear Aligner Attachments Bonded to Monolithic Zirconia: In Vitro Study. J Contemp Dent Pract 2024;25(12):1104-1109.