Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Continuous measurement of carotid-femoral pulse wave velocity (PWVcf.) during general anaesthesia using Doppler: a
Théophile Harlé1,2, Jona Joachim3,4, Pierre Boutouyrie5
1Université Paris Cité, Inserm UMRS 942 Mascot, Paris, F-75006, France. theophile.harle@gmail.com.
Abstract:
This study explores the feasibility of continuous pulse wave velocity (PWV) monitoring during general anaesthesia (GA), particularly in response to blood pressure fluctuations. Our aim is to evaluate whether dynamic PWV can provide new insight to detect cardiovascular risks. From December 2022 to February 2023, continuous carotid and femoral Doppler monitoring was performed on patients scheduled for surgery with GA, to collect PWV data at awakening (PWVAW) and during GA (PWVGA). The study investigated PWV's response to MAP fluctuations using the α-angle, a dynamic stiffness parameter. We evaluated PWV and α-angle efficacy in discriminating between low (CVR-) and high (CVR+) cardiovascular risk patients. Among 43 patients, 41 (95%) had successful PWV measurements. PWVAW was significantly higher than PWVGA (8.1 vs. 7.4 m.s-1, p < 0.0001). This difference vanished after matching MAP levels. A strong correlation was found between PWVAW and PWVGA (r = 0.88, and r = 0.97 at the same MAP levels). PWVGA, α-angle and their product (α x PWVGA) were significantly higher in CVR + patients (8.1 vs. 6.9 m.s-1, p < 0.01; 2.6 vs. 1.3 degrees, p < 0.001; 21.8 vs. 8.1 degrees.m.s-1, p < 0.001, respectively), with AUC values indicating good predictive capabilities for cardiovascular risk (PWVGA: AUC [95%CI] = 0.80 [0.65-0.95]; α-angle: 0.83 [0.69-0.96]; product: 0.86 [0.74-0.97]). Measurement of PWV under GA using carotid and femoral Doppler is a feasible method to continuously assess arterial stiffness under general anaesthesia. Further studies are required to validate the α-angle parameter in different physiological conditions.
Related Concept Videos
Pulse
The pulse serves as a clinical...
Pulse Assessment Sites
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...