Identification of Rare Bacterial Pathogens by 16S rRNA Gene Sequencing and MALDI-TOF MS
Published on: July 11, 2016
Diagnosis Accuracy of Raman Spectroscopy in the Identification of Pathogenic Bacteria
Shanshan Mao1, Yu Zhang1, Chaoqun Chen2
1School of Medical Technology, Xuzhou Medical University, Xuzhou, China.
Abstract:
As an emerging technology, Raman spectroscopy (RS) has been used to identify pathogenic bacteria with excellent performance. The aim of this study was to verify the diagnosis accuracy of RS in identification of pathogenic bacteria. This meta-analysis systematically evaluated the accuracy of RS for identification of pathogenic bacteria. We searched the electronic databases of PubMed and Web of Science to obtain relevant articles; STATA 15.1 was used to analyze all sensitivities, specificies, and their 95% confidence interval (CI). The summary receiver operating characteristic curves (SROC) and area under the curve (AUC) were used to display more performance of RS. Nineteen articles were included according to the inclusion and exclusion criteria. The pooled sensitivity and specificity of RS for the identification of pathogenic bacteria were 0.94 (95% CI, 0.89-0.96) and 0.99 (95% CI, 0.97-0.99). The diagnostic odds ratio (DOR) was 1209 (95% CI, 367-3980), and AUC of SROC was 0.99 (95% CI, 0.98-1.00). For gram-positive bacteria, the sensitivity and specificity of different species ranged from 0.00 to 1.00 and 0.96 to 1.00, with a pooled sensitivity and specificity of 0.96 (95% CI, 0.90-0.98) and 0.99 (95% CI, 0.98-1.00). For gram-negative bacteria, the sensitivity and specificity of different species ranged from 0.30 to 1.00 and 0.92 to 1.00, with a pooled sensitivity and specificity of 0.92 (95% CI, 0.76-0.98) and 0.99 (95% CI, 0.98-1.00). For acid-fast bacteria, the sensitivity and specificity of different species ranged from 0.83 to 1.00 and 0.96 to 1.00, with a pooled sensitivity and specificity of 0.96 (95% CI, 0.84-0.99) and 1.00 (95% CI, 0.96-1.00). RS provides a new method for pathogenic bacteria identification and demonstrates high sensitivity and specificity for most included species.
More Related Videos
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
MALDI-TOF Mass Spectrometry
Matrix-assisted laser desorption ionization (MALDI) is a commonly...