Related Experiment Video
Updated: May 22, 2025

Design and Optimization Strategies of a High-Performance Vented Box
Published on: June 9, 2023
Optimizingin vivodata acquisition for robust clinical microvascular imaging using ultrasound localization microscopy
Chengwu Huang1, U- Wai Lok1, Jingke Zhang1
1Department of Radiology, Mayo Clinic College of Medicine and Science, Rochester, MN, United States of America.
None:
Objective. Ultrasound localization microscopy (ULM) enables microvascular imaging at spatial resolutions beyond the acoustic diffraction limit, offering significant clinical potentials. However, ULM performance relies heavily on microbubble (MB) signal sparsity, the number of detected MBs, and signal-to-noise ratio (SNR), all of which vary in clinical scenarios involving bolus MB injections. These sources of variations underscore the need to optimize MB dosage, data acquisition timing, and imaging settings in order to standardize and optimize ULM of microvasculature. This pilot study aims to investigate the temporal changes in MB signals during bolus injections in both pig and human models to optimize data acquisition for clinical ULM.Approach.Quantitative indices, mainly including individual MB SNR, normalized cross-correlation (NCC) of the MB signal with the point-spread function, and the number of localizable MBs, were developed to evaluate MB signal quality and guide the selection of acquisition timing. The effects of transmitted voltage and dosage on signal quality for MB localization were also explored.Main results. In both pig and human studies, MB localization quality (primarily indicated by NCC) reached a minimum at peak MB concentration, then improved as MB counts decreased during the wash-out phase. An optimal acquisition window was identified by balancing localization quality (empirically, NCC > 0.57) and MB concentration. In the pig model, a relatively short time window (approximately 10 s) for optimal acquisition was identified during the rapid wash-out phase, highlighting the need for real-time MB signal monitoring during data acquisition. The slower wash-out phase in humans allowed for a more flexible imaging window of 1-2 min, while trade-offs were observed between localization quality and MB density (or acquisition length) at different wash-out phase timings. Guided by these findings, robust ULM imaging was achieved in both pig and human kidneys using a short period of data acquisition (3.6 s and 9.6 s of data), demonstrating its feasibility in clinical practice.Significance.This study provides insights into optimizing data acquisition for consistent and reproducible ULM, paving the way for its standardization and broader clinical applications.
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Production Efficiency
Control Systems
At the heart...
Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...
Improving Translational Accuracy
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...

