Computerized Dynamic Posturography for Postural Control Assessment in Patients with Intermittent Claudication
Published on: December 11, 2013
Diagnostic Test Accuracy of Pedal Acceleration Time to Identify Peripheral Artery Disease
Jill Sommerset1, Desarom Teso2, Joseph L Mills3
1Elson S. Floyd College of Medicine, Washington State University Vancouver, WA, USA; Advanced Vascular Centres, Portland, OR, USA.
Objective:
Pedal acceleration time (PAT) is a novel method of using diagnostic ultrasound to evaluate the haemodynamic characteristics of pedal arteries and has potential as an adjunctive vascular testing method. The primary objective of this study was to assess the diagnostic accuracy of PAT in identifying peripheral artery disease (PAD) in a population with clinically suspected PAD.
Methods:
This was a multicentre cross sectional study to estimate the diagnostic test accuracy. Participants with clinically suspected PAD were recruited via consecutive sampling at four centres. Colour duplex ultrasound (reference standard) and toe brachial index (TBI) were measured by a vascular sonographer. A second vascular sonographer, blinded to all other measures, conducted the PAT measurements on the same limb. PAD was defined as a > 50% stenosis in any vessel from the distal aorta to the foot. Sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios were estimated for all PAT values. Receiver operating characteristic curves were also generated.
Results:
One hundred and eighty-eight participants (227 limbs) were recruited, with a mean age of 71 years (standard deviation 10, range 43 - 93) with 56 women (29.8%) including 133 (70.7) limbs having PAD (59%) and 61 (32.4%) claudicants. Area under the curve for PAT: lateral plantar artery 0.72 (0.65 - 0.79), medial plantar artery 0.72 (0.65 - 0.79), dorsal metatarsal artery 0.77 (0.70 - 0.84), arcuate artery 0.71 (0.64 - 0.78), and deep plantar artery 0.73 (0.67 - 0.80). Utilising the worst case PAT measure for the limb for identifying PAD had an AUC of 0.79 (0.74 - 0.85) and positive and negative predictive values of 0.81 (0.57 - 0.89) and 0.66 (0.57 - 0.75), respectively. Area under the curve for the toe brachial index was 0.78 (0.71 - 0.85) and that of ankle brachial index was 0.70 (0.62 - 0.77).
Conclusion:
PAT had an acceptable diagnostic test accuracy as an assessment tool to identify PAD in a population with clinically suspected PAD. All five measures yielded similar accuracy to toe pressure and TBI; however, using the worst case PAT value yielded the highest diagnostic test accuracy of all PAT measures. The PAT diagnostic threshold for the presence of PAD may be revised to > 85 ms to optimise the performance of the test for the identification of PAD.
Related Concept Videos
Pulse Assessment Sites
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Pulse
The pulse serves as a clinical...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: