Novel computed tomography characteristics of dust as well as tiny and small fragments in laser lithotripsy
Naoto Tanaka1, Akash Chitrakar2, Satoshi Kitamura3
1Department of Urology, Hara Genitourinary Hospital, Hyogo prefecture, Kobe City, 650- 0012, Hyogo Prefecture, Japan. naoto.t501@gmail.com.
Purpose:
To evaluate the appearance of dust and stone fragments in the upper urinary tract after retrograde intrarenal surgery (RIRS) on computed tomography (CT) imaging.
Methods:
Human renal stones were implanted into porcine kidneys to assess the characteristics of dust and small fragments on CT imaging. Stone samples were classified as small fragments (2.00-2.36 mm), tiny fragments (1.00-1.40 mm) or dust (≤ 250 μm). Each group was divided into multiple 0.25-g dry weight samples. Twenty-four samples were placed in the upper poles of porcine kidneys with a ureteroscope and characterized using CT. The reconstructed images were evaluated with volume analyzer software to determine stone volume, maximum and mean attenuation values, and standard deviation of the stone attenuation value.
Results:
The mean stone volume decreased with increasing stone size (p < 0.001). The mean attenuation value (depicted in Hounsfield units [HU]) significantly increased with increasing stone size: dust (309.9), tiny fragments (401.2), and small fragments (474.5). The maximum attenuation value (HU) of small fragments (1430.0) was significantly greater than those of tiny fragments (1126.3) and dust (1039.8). As the stone size decreased from the small fragment size to the dust size, the standard deviation of the stone attenuation value significantly decreased.
Conclusion:
As the stone size approaches the that of dust particles, the mean and maximum attenuation values decrease and become more homogeneous. CT and volume analyzer software can be used to distinguish dust from small fragments and assess small residual stones after RIRS.
More Related Videos
11:47Characterization of Surface Modifications by White Light Interferometry: Applications in Ion Sputtering, Laser Ablation, and Tribology Experiments
Published on: February 27, 2013
09:58Spatial Quantification of Drugs in Pulmonary Tuberculosis Lesions by Laser Capture Microdissection Liquid Chromatography Mass Spectrometry LCM-LC/MS
Published on: April 18, 2018
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...