Technical and regulatory challenges in artificial intelligence-based pulse oximetry: a proposed development pipeline
Ana M Cabanas1, Pilar Martín-Escudero2, Josué Pagán3
1Departamento de Física, Universidad de Tarapacá, Arica, Chile.
Abstract:
Pulse oximetry, although generally effective under ideal conditions, faces challenges in accurately estimating peripheral oxygen saturation (SpO2) in complex clinical scenarios, particularly at lower saturation levels and in patients with darker skin pigmentation. Artificial intelligence (AI) offers the potential to improve SpO2 monitoring by enabling more accurate, equitable, and accessible estimations. We highlight key challenges in developing AI-enhanced pulse oximetry, including the need for diverse and representative datasets, refined validation protocols addressing ethical concerns such as algorithmic bias, expanded SpO2 measurement ranges encompassing hypoxaemic levels, and enhanced model interpretability. We emphasise the importance of transitioning from subjective skin tone assessments to quantitative methods to ensure equity and mitigate bias. Finally, we propose a development pipeline and discuss strategies for robust, fair AI-based SpO2 monitoring, including aligning validation with global regulatory frameworks and fostering interdisciplinary collaboration. These advances will improve the reliability and fairness of pulse oximetry, ultimately contributing to enhanced global patient care.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Special considerations while measuring pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...


