Copper-doped NH2-metal-organic frameworks as co-reactant modulating units for a sensitive electrochemiluminescence
Shuai-Fei Zhang1, Yu-Ling Wang1, Xiao-Long Fu1
1College of Chemistry and Chemical Engineering, Xinyang key laboratory of functional nanomaterials for bioanalysis, Xinyang Normal University, Xinyang 464000, China. wyl199499@126.com.
Abstract:
A facile electrochemiluminescence (ECL) immunosensor for the sensitive detection of the prostate-specific antigen (PSA) was constructed based on a co-reactant modulating strategy using a Cu2+-modified NH2-metal-organic framework (NMOF@Cu2+) nanoprobe as a modulating unit. The biconical NMOF@Cu2+ nanoprobe possessed a large number of carboxyl groups, which could be labeled by the target PSA to form a PSA-NMOF@Cu2+ conjugate. Moreover, the nanoprobe could consume K3[Fe(CN)6], resulting in a lower signal of the luminol-K3[Fe(CN)6] ECL system. The bioassay was executed in a split-type mode. First, the competitive immunological recognition reaction with the PSA-NMOF@Cu2+ conjugate as the signal probe was performed in an antibody labeled 96-well plate. In the presence of the target PSA, the PSA competes with the PSA-NMOF@Cu2+ conjugate for immobilization, which determines the amount of PSA-NMOF@Cu2+ conjugates immobilized in the plate and results in different amounts of prefilled K3[Fe(CN)6] being consumed. Subsequently, the above solution was transferred to the detection cell for ECL testing, whereby the ECL signal from the luminol-K3[Fe(CN)6] system reflected the content of the PSA. The developed ECL immunosensor showed high sensitivity for the PSA with a linear response range of 1.0 pg mL-1-10 ng mL-1 and a detection limit of 0.5 pg mL-1. Moreover, the applicability of the present method was demonstrated by the determination of the PSA in human serum.
Related Concept Videos
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Coordination Number and Geometry