Related Experiment Video
Updated: May 22, 2025

08:57
Quantification of Optic Nerve Cross Sectional Area on MRI: A Novel Protocol using Fiji Software
Published on: September 4, 2021
3.9K
Standardized Endoscopic Optic Nerve Decompression: A Comprehensive Radiological and Anatomical Study
Andrzej Sieskiewicz1, Michał Sieśkiewicz2, Bogdan Ciszek3
1Department of Otolaryngology, Medical University of Bialystok, Poland.
Otolaryngologia Polska = the Polish Otolaryngology
|March 17, 2025
Summary
Standardized endoscopic optic nerve decompression (EOND) planning using CT scans ensures precise nerve exposure. This approach minimizes risks of under or over-decompression, improving treatment consistency.
Area of Science:
- Neurosurgery
- Ophthalmology
- Medical Imaging
Background:
- Endoscopic optic nerve decompression (EOND) indications are expanding, but a lack of standardized guidelines leads to variable nerve exposure and difficulty comparing outcomes.
- Current practices for EOND lack uniformity, impacting the reliability and comparability of treatment effectiveness.
Purpose of the Study:
- To propose a standardized methodology for planning and executing endoscopic optic nerve decompression (EOND).
- To leverage radiological and anatomical data for consistent EOND procedures.
Main Methods:
- Fifteen cadaver heads underwent EOND using non-standard oblique computed tomography (CT) reconstruction planes to map the optic canal.
- Decompression targeted the posterior cranial aspect of the optic canal, aiming for 180-degree bone coverage.
- Transcranial access verified decompression adequacy post-procedure.
Main Results:
- Mean distances from decompression endpoint: 8.2 mm to orbital apex, 3.0 mm to cranial optic canal end, 0.4 mm to lateral optico-carotid recess.
- All 30 procedures demonstrated adequate decompression coverage confirmed transcranially.
- The method allowed precise, individualized planning for EOND.
Conclusions:
- Non-standard oblique CT reconstruction planes facilitate accurate, patient-specific EOND planning.
- This technique reduces the likelihood of inadequate or excessive optic nerve decompression.
- The proposed method offers a pathway to standardize optic nerve decompression extent in endoscopic procedures.