Related Experiment Video
Updated: May 22, 2025

Capillary Electrophoresis Separation of Monoclonal Antibody Isoforms Using a Neutral Capillary
Published on: January 16, 2017
Predictive mechanistic model for separation of monoclonal antibody, fab fragment, and aggregate species on multimodal
Lalita Kanwar Shekhawat1,2, Todd Markle1, Jean-Luc Maloisel1
1Cytiva Sweden AB, Research and Development Division, Resins and Technologies Science, Uppsala, Sweden.
Abstract:
The specific selectivities offered by multimodal ligands drive the increased application of multimodal chromatography in the purification of complex new "multispecific" antibodies, which requires improved understanding of the protein-multimodal ligand interaction mechanism. In the present study, a mechanistic model is developed to predict monoclonal antibody (mAb1)-Fab fragment (Fab) and heterogeneous aggregates separation on Capto™ MMC ImpRes multimodal resin based on the general rate model coupled with the proposed preferential interaction (PI) analysis-based Langmuir non-linear binding model. The model input value of binding parameters is obtained from Perkin et al. developed PI model, fit to the characteristic 'U'-shaped curve for isocratic retention factors of mAb1, Fab, and aggregates as a function of NaCl salt concentrations. The model successfully simulates mAb1 and Fab elution peaks, whereas in the absence of deconvoluted peaks of heterogeneous aggregates, aggregates are modeled as a single species, giving satisfactory prediction of elution peak position, describing the average of the multiple (majority as double peaks) aggregate elution peaks. The physical significance of model estimated binding parameters is obtained from model estimated total number of released counter salt ions and water molecules for each species during binding, found to be consistent with their isocratic retention data. The underlying mechanism of double peak elution of aggregates during linear gradient elution was investigated based on mechanistic model estimated equilibrium constant. The proposed predictive mechanistic model was successfully validated by predicting mAb1, Fab, and aggregates elution peaks for the multimodal column operated in hydrophobic interaction mode and can be successfully implemented for process development.
More Related Videos
10:50Purification and Analytics of a Monoclonal Antibody from Chinese Hamster Ovary Cells Using an Automated Microbioreactor System
Published on: May 1, 2019
10:33Isolation and Characterization Of Chimeric Human Fc-expressing Proteins Using Protein A Membrane Adsorbers And A Streamlined Workflow
Published on: January 8, 2014
Related Concept Videos
Affinity Chromatography
Principles Of Column Chromatography
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Overview Of Cell Separation And Isolation