A Flexible Multi-Sensor Device Enabling Handheld Sensing of Heart Sounds by Untrained Users
None:
Heart valve disease has a large and growing burden, with a prognosis worse than many cancers. Screening with a traditional stethoscope is underutilised, often inaccurate even in skilled hands, and requires time-consuming, intimate examinations. Here, we present a handheld device to enable untrained users to record high-quality heart sounds without requiring patients to undress. The device incorporates multiple high-sensitivity sensors embedded in a flexible substrate, placed at key chest locations by the user. To address challenges from localised heart sound vibrations and noise interference, we developed time-frequency signal quality algorithms that automatically select the best sensor in the device and reject recordings with insufficient diagnostic quality. A validation study demonstrates the device's effectiveness across a diverse range of body types, with multiple sensors significantly increasing the likelihood of a successful recording. The device has the potential to enable accurate, accessible, low-cost heart disease screening.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...