A New Contact Structure and Dielectric Recovery Characteristics of the Fast DC Current-Limiting Circuit Breaker
Zhiyong Lv1, Xiangjun Wang1, Jinwu Zhuang1
1College of Electrical Engineering, Naval University of Engineering, Wuhan 430000, China.
Abstract:
In order to solve the problem of slow dielectric recovery caused by large arc energy when interrupting a high rising rate fault current in a fast DC current-limiting circuit breaker (FDCCLCB), a new contact structure with multi-point static contacts in parallel is proposed. Based on the principle of parallel multi-point contacts, the new structure can form the arc mode during multi-point arcing when the contacts are separated, reduce the arc energy of each finger contact, effectively reduce the ablation effect of the arc on the contact, and improve dielectric recovery ability after the arcing of the contact. Using high-speed camera technology to photograph the arc shape of the new contact, the assumption of multi-point arcing is verified, and a dielectric recovery experimental platform is built to study the dielectric recovery characteristics of the new contact structure. The experimental results show that, when the arc energy is 3.6 J and the dielectric recovery time is 60 µs, the critical field strength reaches 1.5 V/µm; when the arc energy is increased to 22 J, the critical field strength is 0.6 V/µm under the same dielectric recovery time. It can be seen that reducing the arc energy of the contact can effectively improve the dielectric recovery ability of the contact. Due to the magnetic field coupling between each finger contact, the current and arc energy on each contact are different, resulting in a weak point of breakdown and finger contacts at two ends. Finally, in order to solve the problem of large contact current at two ends, a solution to adjust the spacing among contacts is proposed. A genetic algorithm is used to optimize the spacing parameters. The optimization results show that the maximum arc energy of the finger contact is only 19.07% of the total arc energy, which greatly reduces the arc energy of the contact and improves the post-arc recovery ability of the contact.
More Related Videos
11:44Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
07:51Dielectric RheoSANS — Simultaneous Interrogation of Impedance, Rheology and Small Angle Neutron Scattering of Complex Fluids
Published on: April 10, 2017
Related Concept Videos
Circuit Breaker and Fuse Selection
In high-voltage systems,...
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Series R—L Circuit Transients
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
Directional Relays
Overcurrent Relays
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...