Blood pressure waveform morphology assessed using a transmission line model and harmonic distortion analysis
Nicholas Milkovich1, Gary F Mitchell2, Bela Suki3
1Department of Mechanical Engineering, Boston University, 110 Cummington Mall, Boston, MA, USA.
None:
A major determinant of blood pressure waveform (BPW) morphology is vascular impedance, governed by material properties of the arterial wall and hemodynamics of blood flow. Analysis of BPW morphology can be an effective means of assessing cardiovascular health. A transmission line model of the mechanical impedance of the arterial tree was implemented to recreate physiologically realistic BPWs. We then examined the sensitivity of existing vascular measures, including augmentation index (AI), pulse wave velocity (PWV), and the recently proposed harmonic distortion (HD), to structural and mechanical parameters of vessel walls and blood flow. All three measures are primarily sensitive to structural stiffness while HD and AI also correlate strongly with geometric parameters. Further, in a simulated set of randomly constructed arterial trees using model parameters within a physiological range, the indexes are strongly correlated with stiffness. When controlling for all confounding factors, HD demonstrates a stronger correlation with arterial stiffness than AI for stiffness values higher than the average. Our study provides a mechanistic understanding of the determinants of AI and HD, with the latter being a promising measure of cardiovascular risk due to its ease of calculation and access, meeting key limitations set by AI and PWV.
Related Concept Videos
Lossy Lines and Overvoltages
Attenuation
When constant series resistance and shunt conductance are present, voltage and current equations are modified. The propagation constant indicates that voltage and current waves consist of both forward and backward traveling components. These waves attenuate as they propagate, with the attenuation factor related to the resistance and conductance. In a...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Traveling Waves: Lossless Lines
Boundary Conditions: Lossless Lines
At the receiving end, the boundary condition states that the voltage equals the product of the receiving-end impedance and current. This relationship is expressed as a function of the incident and...
Transmission-Line Differential Equations
Line Section Model
A circuit representing a line section of length Δx helps in understanding the transmission line parameters. The voltage V(x) and current i(x) are measured...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...