Acute Clinical Adverse Outcomes Associated With the Cor-Knot
Konmal Ali1, Syed Shaheer Ali1, Sara Sakowitz1
1Cardiovascular Outcomes Research Laboratories (CORELAB), University of California, Los Angeles, California.
The Cor-Knot device, used in cardiac surgery, has reported adverse events including malfunction, valve insufficiency, and hemorrhage. Increased device training is recommended to minimize complications.
Area of Science:
- Cardiovascular Surgery
- Medical Device Safety
Background:
- Manual knot tying in cardiac valve operations is associated with increased operative times and costs.
- The Cor-Knot device offers an alternative using an automatic titanium fastener system.
- Adverse outcomes associated with the Cor-Knot device have not been previously characterized.
Purpose of the Study:
- To characterize adverse events associated with the Cor-Knot device.
- To identify the types and frequencies of complications related to Cor-Knot usage.
- To analyze factors contributing to adverse incidents involving the Cor-Knot.
Main Methods:
- A nationally representative cohort of adverse events from 2015-2023 was analyzed using the Manufacturer and User Facility Device Experience database.
- Reports were screened to identify incident types and complications.
- Device and patient complications were categorized and reported as proportions.
Main Results:
- An increasing trend in reported adverse events was observed from 2015 to 2023.
- Malfunction (63.5%) was the most frequent device incident, often due to misfire or usage issues.
- Patient complications included valve insufficiency (10.8%), foreign body presence (8.1%), and hemorrhage (2.7%).
Conclusions:
- Malfunction, particularly misfire and usage issues, is a primary concern with the Cor-Knot device.
- Patient complications such as valve insufficiency, foreign body presence, and hemorrhage require attention.
- Enhanced device training is crucial to minimize adverse events as Cor-Knot utilization grows.