Related Experiment Video
Updated: May 21, 2025
![Technical Aspect of the Automated Synthesis and Real-Time Kinetic Evaluation of [11C]SNAP-7941](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F59557.jpg&w=3840&q=50)
Technical Aspect of the Automated Synthesis and Real-Time Kinetic Evaluation of [11C]SNAP-7941
Published on: April 28, 2019
Development and Validation of an HPLC Method to Determine Chemical and Radiochemical Purity of [18F]Florbetazine
Fuhai Wu1,2, Xiaoming Wang2, Huan Chen2
1Department of Chemistry, College of Chemistry and Life Science, Center of Excellence for Environmental Safety and Biological Effects, Beijing University of Technology, Beijing, China.
Abstract:
[18F]Florbetazine injection, a radiotracer that could target Aβ plaques and achieve diagnosis of Alzheimer's disease (AD), is a novel positron emission tomography (PET) imaging agent currently in the investigational new drug (IND) application stage. The active ingredient of [18F]Florbetazine injection, [18F]Florbetazine, is a diaryl-azine derivative. Chemical and radiochemical purity is critical quality attributes (CQAs) for [18F]Florbetazine injection, and thus, we have developed and validated a relevant HPLC method. This study describes the specificity, linearity, accuracy, repeatability, and limit of quantification (LOQ) of the HPLC method. The stability of three sample batches was investigated using the established method. The validation results demonstrated the accuracy, precision, and sensitivity of the method, making it suitable for implementation as part of the quality control (QC) process for [18F]Florbetazine injection. The stability of three sample batches revealed a decrease in concentration and radiochemical purity over 10 h. However, all samples maintained a radiochemical purity of over 90% after 10 h. The results provided a foundation for establishing quality standards for [18F]Florbetazine injection. The same methodology employed in this study could be applied and modified for QC protocols of other 18F-labeled radiopharmaceuticals.
More Related Videos
10:33Development of Inhibitors of Protein-protein Interactions through REPLACE: Application to the Design and Development Non-ATP Competitive CDK Inhibitors
Published on: October 26, 2015
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Related Concept Videos
High-Performance Liquid Chromatography: Instrumentation
Data Validation
Key parameters for method validation include:
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
Principles Of Column Chromatography