Related Experiment Video
Updated: May 21, 2025

Creating Radio-cephalic Arteriovenous Fistula in the Forearm with a Modified No-Touch Technique
Published on: April 1, 2022
A Comparative Study of the Ease of Radial Artery Cannulation Using the Palpation Method in Patients Undergoing
Rashmi Dubey1, Vikramjit Singh1, Monica Khetarpal1
1Anaesthesiology, All India Institute of Medical Sciences, Raipur, Raipur, IND.
Abstract:
Introduction Radial artery cannulation is performed for continuous blood pressure monitoring and blood gas measurements in the operating room, critical care unit, and postoperative period. Various factors determine the artery used for cannulation, including accessibility, ease of placement, collateral flow, risk of infection, and embolic phenomena. Most anaesthesiologists consider anaesthesia induction the most likely timing of hemodynamic instability. These hemodynamic changes may affect the blood vessels in terms of their lumen and pulsation, thus posing a challenge to the anaesthesiologist for successful arterial cannulation. In the present study, we aim to assess whether these hemodynamic changes, consequent to the induction of general anaesthesia, significantly affect the success rate of radial artery cannulation compared to the success rate if performed before the induction of general anaesthesia using the palpation method. Materials and methods A total of 60 eligible and consenting ASA-PS I & II (American Society of Anaesthesiologists Physical Status I & II) patients undergoing elective surgery (which requires invasive blood pressure monitoring) under general anaesthesia were prospectively randomized into two groups, Pre-I (Pre-induction) and Post-I (Post-induction), using a random selection method. In the Pre-I group, radial artery cannulation was performed before induction of anaesthesia, while in the Post-I group, radial artery cannulation was performed after induction of anaesthesia. The data, including the success rate of arterial cannulation, the number of attempts required to cannulate the radial artery successfully, and the time taken to successfully cannulate the radial artery, were obtained and analysed. Results Demographic variables such as mean age, weight, height, BMI (body mass index), and the ASA-PS were comparable across the groups, and the differences were not statistically significant. In the Pre-I group, of 30 patients, 28 were in ASA class I, and two were in ASA class II; the respective numbers in the Post-I group were 27 and 3. Of all 60 patients, the radial artery was successfully cannulated in 54 patients - 26 in the Post-I group and 28 in the Pre-I group. The number of attempts for cannulation was one attempt in 23 patients and two attempts in three patients in the Post-I group; the respective numbers for the Pre-I group were 26 and 2. The mean time for cannulation was 14.38 seconds in the Post-I group and 12.67 seconds in the Pre-I group. The complications (hematoma at the site of cannulation) related to radial cannulation were noted in three patients - two in the Post-I group and one in the Pre-I group. Conclusion Radial artery cannulation can be performed with comparable ease, before and after the induction of anaesthesia, in patients belonging to ASA-PS I & II.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Pre-Procedural Guidelines for Assessing Blood Pressure