Photon-counting CT yields superior abdominopelvic image quality at lower radiation and iodinated contrast doses
Fides Regina Schwartz1, Steve Bache2, Rachel Lee2
1Department of Radiology, Brigham and Women's Hospital, 75 Francis Street, Boston, MA, 02115, USA. frschwartz@bwh.harvard.edu.
Background:
Photon-counting detector (PCD) computed tomography (CT) has been shown to provide better image quality at lower radiation and intravenous contrast doses than energy-integrating detector (EID) CT in adult patients. There is limited data on these benefits for the pediatric population especially for abdominopelvic CT examinations.
Objective:
This study examines a reduced weight-based iodinated contrast dosing strategy in pediatric abdominopelvic CT on a PCD-CT system compared to standard dosing protocols on EID-CT using 1 mL/kg and 2 mL/kg, respectively. Image quality is assessed using both quantitative and qualitative measures. We also compare the radiation dose profile between the two PCD-CT and EID-CT cohorts.
Materials And Methods:
This HIPAA-compliant, IRB-approved, retrospective study included pediatric patients (≤18 years of age) who underwent contrast-enhanced CT examinations of the abdomen and pelvis for routine clinical care (01/2022 - 01/2023) in the portal-venous phase on a PCD-CT (NAEOTOM Alpha; Siemens Healthineers). Inclusion criteria included a similar prior examination within 12-months on a dual-source EID-CT scanner from the same vendor. All PCD-CT and EID-CT scans were acquired using weight-based dosing for intravenous contrast media, 1 mL/kg and 2 mL/kg, respectively, based on institutional protocols. Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were measured in the aorta, portal vein, liver parenchyma, and skeletal muscle. Three pediatric radiologists qualitatively evaluated each scan for overall image quality, noise, and contrast on a scale of 0-100. Confidence in small structure detection (common bile duct) was also rated on a scale of 0-3. Radiation doses (size-specific dose estimate (SSDE)) were calculated. Statistical analysis included paired t-tests and a mixed linear effects model to account for patient age, sex, and X-ray tube voltage. A P<0.05 indicated statistical significance.
Results:
A total of 49 patients were included (24 female; mean [SD] age 9.9 [6.3] years, range 0.6-18 years). Compared to EID-CT, PCD-CT had a higher mean SNR in the portal vein (23.4 [SD=9.3] vs 17.2 [SD=7.4], P<0.001), aorta (23.4 [SD=11.6] vs 17.7 [10.1], P=0.017), hepatic parenchyma (15.2 [SD=5.6] vs 13.2 [5.1], P=0.016), and skeletal muscle (5.7 [SD=3.1] vs 4.5 [SD=3.1], P=0.01). Compared to EID-CT, PCD-CT also had a higher mean CNR in the portal vein (27.5 [SD=9.6] vs 22.1 [SD=21.1], P=0.003), aorta (27.3 [SD=9.6] vs 22.3 [SD=11.8], P=0.004), hepatic parenchyma (20 [SD=6.9] vs 16.9 [SD=8.5], P=0.013), and skeletal muscle (14.6 [4.9] vs 12.1 [5.6], P=0.008). Overall image quality, image noise, and small structure detection confidence scores were higher on PCD-CT than EID-CT (P=0.037, P<0.001, and P=0.006, respectively). Mean SSDE for PCD-CT was lower than EID-CT (9.1 mGy [SD=4.3] vs 11 mGy [5.9], P=0.012).
Conclusion:
Compared with EID-CT, contrast-enhanced pediatric abdominopelvic CT offers improved subjective and objective image quality, even at lower radiation doses and reduced intravenous contrast medium volumes.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
X-ray Imaging
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Ultrasonography
During an ultrasonography procedure, a handheld device called...