LI-RADS for diagnosing hepatocellular carcinoma by contrast-enhanced US with SonoVue and Sonazoid-a single center

Chen Lin1, Xiao-Huan Yang2, Hong-Yan Zhai1

  • 1Tianjin Medical University General Hospital, Tianjin, China.

PubMed

Insights

A modified algorithm using Sonazoid contrast-enhanced ultrasound (CEUS) with Kupffer-phase imaging significantly improved hepatocellular carcinoma (HCC) detection sensitivity compared to standard SonoVue CEUS LI-RADS. This enhanced HCC diagnostic performance was achieved without compromising specificity.

Area of Science:

  • Hepatobiliary imaging
  • Diagnostic performance evaluation
  • Hepatocellular carcinoma (HCC) detection

Background:

  • Contrast-enhanced ultrasound (CEUS) is crucial for diagnosing hepatocellular carcinoma (HCC).
  • Current LI-RADS (Liver Imaging Reporting and Data System) guidelines have limitations in HCC diagnosis.
  • Sonazoid CEUS offers unique Kupffer-phase imaging, potentially improving diagnostic accuracy.

Purpose of the Study:

  • To compare the diagnostic performance of two CEUS algorithms for HCC.
  • Evaluate SonoVue-CEUS LI-RADS (version 2017) against a modified Sonazoid-CEUS algorithm incorporating Kupffer-phase findings.

Main Methods:

  • Prospective, single-center study of high-risk HCC patients.
  • Patients underwent both SonoVue-CEUS and Sonazoid-CEUS.
  • Liver observations were categorized using both standard and modified LI-RADS algorithms, with pathologic confirmation as the reference standard.

Main Results:

  • The modified Sonazoid-CEUS LI-RADS demonstrated significantly higher sensitivity (82% vs. 65%) and accuracy (85% vs. 71%) compared to SonoVue-CEUS LI-RADS.
  • No significant difference in specificity was observed between the two methods (93% vs. 87%).
  • The modified algorithm upgraded observations based on Kupffer-phase defect characteristics.

Conclusions:

  • Incorporating Kupffer-phase findings in Sonazoid-CEUS LI-RADS enhances HCC diagnostic sensitivity.
  • This modified approach achieves higher sensitivity without a reduction in specificity.
  • Sonazoid-CEUS with Kupffer-phase analysis offers improved diagnostic capabilities for HCC.
Abstract