Related Experiment Video For CT
Updated: May 21, 2025

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Imaging assessment of malignancy screening using computed tomography and diffusion-weighted whole-body imaging with
Takeshi Mochizuki1, Koichiro Yano2, Katsunori Ikari2
1Department of Orthopaedic Surgery, Kamagaya General Hospital, Chiba, Japan.
Objectives:
To investigate differences in information obtained from plain computed tomography (CT) and diffusion-weighted whole-body imaging with background body signal suppression (DWIBS) during malignancy screening in patients with rheumatoid arthritis.
Methods:
We enrolled 524 patients with RA who underwent plain CT from the chest to the pelvis and DWIBS. CT and DWIBS were performed within 3 months of each other. Rheumatologists, radiologists, and pulmonologists interpreted the plain CT and DWIBS images.
Results:
The prevalence of malignancy was 3.1%. Prostate, lung, breast, uterine, ovarian, and fallopian tube cancers were detected in 7, 4, 2, 1, 1, and 1 patient, respectively. The sensitivities of CT and DWIBS were 75.0% and 93.8%, respectively (P = .333). The specificities of CT and DWIBS were 76.0% and 85.8%, respectively (P < .001). The prevalence rates of interstitial lung disease, colonic diverticula, and kidney stones on CT were 17.6%, 27.1%, and 19.1%, respectively. The prevalence of lymphadenopathy in patients who underwent DWIBS was 3.6%.
Conclusion:
This study suggests that DWIBS is superior to or equivalent to CT for malignancy screening. Our findings have important implications for imaging-based screening and can help address cancer-related issues in rheumatoid arthritis treatment.
Related Concept Videos
X-ray Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Magnetic Resonance Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT

