Related Experiment Video
Updated: May 21, 2025

Thermal Imaging to Study Stress Non-invasively in Unrestrained Birds
Published on: November 6, 2015
Evaluation of non-invasive sensors for monitoring core temperature
Shavin S Thomas1, Katharyn L Flickinger2, Jonathan Elmer3,4,5
1University of Pittsburgh School of Medicine, Pittsburgh, PA, USA.
Abstract:
We evaluated the accuracy and precision of zero-heat flux (ZHF) and dual sensor (DS) non-invasive temperature probes in intensive care unit (ICU) patients undergoing hypothermic temperature control, hypothesizing that both devices would accurately estimate core temperature. In a single-center prospective cohort study, we enrolled 35 ICU patients and applied continuous, non-invasive ZHF and/or DS probes to the lateral forehead or anterior chest to collect 358 observations. Conditions potentially influencing temperature estimation were recorded. Using Bland-Altman analysis with multiple paired observations per individual, we compared the bias between non-invasive probes and direct core temperature measurements. Lin's concordance coefficient (LCC) was computed to quantify precision. The mean bias between the ZHF probe and invasive temperature was + 0.98 °C; for the DS probe, it was - 2.19 °C. In hypothermic patients, the ZHF probe's accuracy improved (bias + 0.28 °C, LCC 0.86), while the DS probe remained inaccurate (bias - 2.52 °C, LCC 0.07). Clinical confounders like vasoactive agents or temperature control devices did not consistently affect bias, accuracy, or precision. Neither the ZHF nor DS non-invasive probes provided sufficient accuracy or precision to guide clinical decisions in the ICU. These results contrast with previous studies reporting biases within ± 0.5 °C. However, the ZHF probe showed promising limited deviation, especially in hypothermic patients.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...