Effect of bias flow rate on gas transport during high-frequency oscillatory ventilation
Abstract:
Ventilatory support with low tidal volume, high-frequency oscillatory ventilation (HFOV) usually uses a bias flow system to provide fresh gas. Although the bias flow rates (Vbf) used previously have varied widely among experimental configurations, the precise role of the bias flow in HFOV-mediated gas transport has not been defined. We assessed the effect of bias flow rate on gas transport during HFOV by measuring CO2 removal rate (MCO2) in anesthetized, paralyzed dogs, using a wide range of bias flow rates (0.7-28.9 L X min-1). When a fixed tidal volume of 40 ml was applied at HFOV frequencies of 2-12 Hz, MCO2 was proportional to the time-averaged alveolar-bias flow CO2 concentration difference. Thus, when Vbf was reduced below a value which resulted in a substantial increase in bias flow CO2 concentration, MCO2 was reduced. These findings are consistent with a simple framework in which the relative magnitudes of the resistances to gas transport of the airways and of the bias flow (1/Vbf) determine the contribution of the bias flow rate to overall gas transport during HFOV. This relationship may be employed to assess the intra-airway contribution to HFOV-mediated gas transport at any bias flow rate, and may therefore allow comparison of results from experiments utilizing various bias flow rates.
Related Concept Videos
Poiseuille's Law and Reynolds Number
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Turbulent Flow: Problem Solving
Temperature is a key factor in CO2 solubility. In this case, the CO2 gas and the liquid are cooled to 20°C. Lower temperatures enhance...