Related Experiment Video
Updated: May 20, 2025

Author Spotlight: Streamlining Visual Dynamics to Simplify Molecular Dynamics Simulations Using Gromacs
Published on: August 9, 2024
V3O7·H2O as a Cathode Material for Aqueous Mg2+/Na+ Hybrid Electrochemical Cells
Daniela Söllinger1, Julie Lam Chen1, Jakub Zalesak1
1Chemistry and Physics of Materials, University of Salzburg, Salzburg 5020, Austria.
Abstract:
To improve safety and sustainability aspects of today's energy storage solutions, aqueous post-lithium-ion electrochemical cells are promising concepts. In this context, we synthesize hydrated vanadium oxide (V3O7·H2O) via a hydrothermal process and investigate its electrochemical properties as a cathode in aqueous post-lithium-ion hybrid cells. This active material exhibits an excellent initial specific capacity of 404 mAh·g-1 at a practical current density of 100 mA·g-1 and a promising stability of 123 mAh·g-1 at a current density of 1 A·g-1 after 500 cycles upon Mg2+ and Na+ cointercalation. The insertion characteristics of this hybrid cell are investigated by cyclovoltammetry, operando XRD, and post-mortem transmission electron microscopy measurements. The results suggest that Na+ is inserted preferentially at lower potentials and that its effect fades quickly, while the Mg2+ contribution enables stable cycling, resulting in a competitive capacity retention of 73% after 500 cycles. In addition, we find that the charge transfer resistances are about one hundred times smaller in aqueous than in pure organic electrolyte as measured by electrochemical impedance spectroscopy. These results demonstrate that V3O7·H2O is a suitable cathode material for aqueous Mg2+/Na+ hybrid cells, enabling a performance that is comparable to cathodes in less sustainable and less safe organic electrolytes with respect to capacity and stability and is superior in transport-related properties.
Related Concept Videos
Visual System
Once through the pupil, the light passes through the lens, a...
In Vitro Fertilization
The IVF process begins with ovarian stimulation, during which reproductive endocrinologists prescribe hormonal medications to stimulate the ovaries to produce multiple eggs instead of the single...
Drag
P-value
P-value stands for the probability value. P-value is the probability that, if the null hypothesis is true, the results from another randomly selected sample will be as extreme or more extreme as the results obtained from the given sample.
A large P-value calculated from the data indicates to not reject the null hypothesis. But a higher P-value does not mean that the null hypothesis is true. The smaller the P-value, the more...
Viscosity
The SI unit of viscosity is...
Venules
Venules are much smaller in diameter compared to their larger counterparts, the veins. They are generally 8 to 100 micrometers in diameter, significantly smaller than the size of veins. The walls of venules are thin, consisting of the endothelium, a thin layer of connective tissue, and occasionally a few smooth muscle cells. This structural simplicity is a stark contrast...

