Related Experiment Video
Updated: Aug 6, 2026

Scanning Skeletal Remains for Bone Mineral Density in Forensic Contexts
Published on: January 29, 2018
Opportunistic measurement of sagittal abdominal diameter with bone densitometry predicts death and cardiovascular
William D Leslie1, Fatima Zarzour1, Lisa M Lix1
1University of Manitoba, Rady College of Medicine, Winnipeg, MB R3E 0W2, Canada.
Abstract:
Supine sagittal abdominal diameter (SAD), also known as abdominal height, has been proposed as a simple measure for assessing abdominal adiposity. We aimed to determine whether SAD from DXA performed for osteoporosis assessment predicts major adverse cardiovascular events (MACEs) using the population-based DXA registry for the Province of Manitoba, Canada. The study population comprised 72 974 individuals aged 40 yr and older with baseline DXA assessment between February 1999 and March 2018. Incident MACE (composite of all-cause mortality, acute myocardial infarction [MI], non-hemorrhagic stroke) was ascertained from linked healthcare databases. During mean 8.4 yr follow-up (611 862 person-years), 14 457 (18.8%) individuals experienced incident MACE. Risk stratification was greatest with SAD/weight ratio, with area under the curve (AUC) for MACE and its components ranging from 0.582 for acute MI to 0.620 for death (all p < .001), all significantly better than with BMI (p < .001). In multivariable-adjusted models, each SD increase in SAD/weight was associated with increased risk for MACE (hazards ratio [HR] 1.20, 95% CI 1.18-1.22), death (HR 1.22, 95% CI 1.20-1.25), acute MI (HR 1.19, 95% CI 1.14-1.24), and stroke (HR 1.17, 95% CI 1.12-1.22). A linear gradient was seen across SAD/weight quintiles (all p-trend < .001), with adjusted HR for MACE 1.61 (95% CI 1.50-1.72) for highest vs lowest quintile. Results were similar when further adjusted for BMI in non-obese and obese individuals (p-interaction for obesity = .141) and in both women and men (p-interaction for sex = .471). In conclusion, SAD measured opportunistically at the time of DXA testing is predictive of death and major cardiovascular events in individuals undergoing osteoporosis assessment.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure

