Fixed CPAP at 10 cmH 2O May Replace Manual Titration in Moderate to Severe OSA Patients: A Preliminary Randomised
Wang Lu1, Yan Chen1, Qishan Wei1
1State Key Laboratory of Respiratory Disease, Guangzhou Medical University, Guangzhou, China.
Background And Objectives:
Patient compliance with continuous positive airway pressure (CPAP) is similar using manual-titrated pressure compared to auto-titration, although auto-titration pressures are usually 2-5 cmH2O higher than manual pressure, indicating that CPAP moderately higher than the optimal pressure will not necessarily impair compliance. We try to find the tolerable highest CPAP which does not increase respiratory effort based on changes in lung volume, diaphragm electromyography (EMG) and breathing sensations in healthy volunteers and OSA patients to simplify pressure titration.
Methods:
Part 1, 12 healthy subjects and 16 OSA patients were enrolled in the measurement of expiratory reserve volume, diaphragm EMG, and expiratory muscle EMG at different CPAP levels. Breathing difficulty during different CPAP levels was assessed using a customised questionnaire in 35 healthy subjects and 33 OSA patients. Part 2, a two-night randomised crossover double-blind trial using the tolerable highest CPAP (10 cmH2O) based on the results derived from Part 1 and the manually titrated pressure was performed in 25 OSA patients.
Results:
End expiratory lung volume increased significantly with increasing CPAP. In general, diaphragm EMG changed little when CPAP ≤ 10 cmH2O. Expiratory muscle activity appeared when CPAP > 12 cmH2O. There was no significant difference in subjective sensation of breathing difficulty with CPAP ≤ 10 cmH2O. Sleep structure, AHI, and patient preference with 10 cmH2O CPAP were not different from those under titrated pressure.
Conclusions:
This study suggests that most patients with moderate to severe OSA can be effectively treated with CPAP at an initial pressure of 10 cmH2O without pressure titration.
Trial Registration:
ClinicalTrials.gov identifier: NCT04925466.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes: