Related Experiment Video
Updated: Jul 15, 2026

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring
Published on: December 9, 2010
Accelerated diffusion-weighted imaging of the prostate employing echo planar imaging with compressed SENSE based
Yannik Christian Layer1, Petra Mürtz2, Alexander Isaak2
1Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany. yannik.layer@ukbonn.de.
Abstract:
Aim was to evaluate accelerated diffusion-weighted imaging (DWI) of the prostate using echo planar imaging with compressed SENSE based reconstruction (EPICS) and assess its performance in comparison to conventional DWI with parallel imaging. In this single-center, prospective study, 35 men with clinically suspected prostate cancer underwent prostate MRI at 3T. In each patient, two different DWI sequences, one with 3 b-values (b = 100, 400, 800s/mm²) for ADC-calculation and one with b = 1500s/mm², were acquired with conventional SENSE and with EPICS. Quantitative evaluation was done by regions-of-interest (ROIs) analysis of prostate lesions and normal appearing peripheral zones (PZ). Apparent contrast-to-noise (aCNR) and apparent signal-to-noise ratios (aSNR) were calculated. Mean ADC and coefficient of variation (CV) of ADC were compared. For qualitative assessment, artifacts, lesion conspicuity, and overall image quality were rated using a 5-point-Likert-scale (1: nondiagnostic to 5: excellent). Additionally, the Prostate Imaging Reporting and Data System (PIRADS 2.1) was rated for DWI. The average total scan time reduction with EPICS was 43%. Quantitative analysis showed no significant differences between conventional SENSE and EPICS, neither for aSNRLesion (e.g. b1500conv: 24.37 ± 10.28 vs. b1500EPICS: 24.08 ± 12.2; p = 0.98) and aCNRLesion (e.g. b1500conv:9.53 ± 7.22 vs. b1500EPICS:8.88 ± 6.16; p = 0.55) nor for aSNRPZ (e.g. b1500conv:15.18 ± 6.48 vs. b1500EPICS: 15 ± 7.4; p = 0.94). Rating of artifacts, lesion conspicuity, overall image quality and PIRADS-scores yielded comparable results for the two techniques (e.g. lesion conspicuity for ADCconv: 4(2-5) vs. ADCEPICS 4(2-5); p = 0.99 and for b1500conv: 4(2-5) vs. b1500EPICS 4(2-5); p = 0.25). Overall, accelerated DWI of the prostate using EPICS significantly reduced acquisition time without compromising image quality compared to conventional DWI.
More Related Videos
15:48Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
06:08A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound
Published on: March 21, 2025
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies II: Ultrasonography