Carotid peak flow velocity variation as a surrogate of aortic peak flow velocity variation in a pediatric population

Federico Cristiani1, Juan Pablo Bouchacourt2, Juan Riva2

  • 1Facultad de Medicina, Centro Hospitalario Pereira Rossell, Universidad de la República, Montevideo, Uruguay. federicocristiani9@gmail.com.

BMC Anesthesiology
|March 26, 2025
PubMed

Insights

Carotid peak velocity variation (ΔVpeakCar) is a reliable surrogate for aortic peak velocity variation (ΔVpeakAo) in schoolchildren. However, its accuracy decreases in younger children, indicating age-dependent reliability.

Area of Science:

  • Pediatric Anesthesiology
  • Cardiovascular Physiology
  • Hemodynamic Monitoring

Background:

  • Carotid peak velocity variation (ΔVpeakCar) is explored as an alternative to aortic peak velocity variation (ΔVpeakAo) in pediatric patients.
  • Children's physiological and anatomical variability necessitates evaluating the age-dependent predictive value of ΔVpeakCar.
  • The study hypothesizes that the surrogate capability of ΔVpeakCar for ΔVpeakAo changes across childhood development stages.

Purpose of the Study:

  • To assess the concordance between ΔVpeakCar and ΔVpeakAo.
  • To evaluate the tracking ability of ΔVpeakCar as a surrogate for ΔVpeakAo across different pediatric age groups.
  • To determine the reliability of ΔVpeakCar in pediatric patients aged 0-12 years.

Main Methods:

  • Inclusion of pediatric patients aged 0-12 years, stratified into three groups: under 12 months (G1), 12-60 months (G2), and over 60 months (G3).
  • Measurement of maximal and minimal aortic and carotid peak flow post-anesthesia induction and mechanical ventilation.
  • Statistical analysis including Pearson correlation, linear regression, Bland-Altman analysis, and 4-quadrant/polar vector analysis to assess concordance and tracking.

Main Results:

  • Correlation coefficients (r) between ΔVpeakAo and ΔVpeakCar were 0.44 (G1), 0.56 (G2), and 0.85 (G3), with significant p-values (<0.001) for all groups.
  • Bland-Altman analysis revealed mean biases of -0.37 (G1), -0.07 (G2), and 0.55 (G3), with decreasing limits of agreement from G1 to G3.
  • Concordance rates were high, particularly in older children: 93% (G1), 95% (G2), and 100% (G3).

Conclusions:

  • ΔVpeakCar demonstrates good correlation and tracking ability with ΔVpeakAo in schoolchildren (G3).
  • The reliability of ΔVpeakCar as a surrogate for ΔVpeakAo is significantly reduced in younger children (G1 and G2).
  • Age-specific considerations are crucial when utilizing ΔVpeakCar for hemodynamic monitoring in pediatric populations.
Abstract