Related Experiment Video
Updated: May 20, 2025

Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
Balancing Image Quality and Iodine Intake: Insights from CT Spectral Imaging of the Portal Vein
Linjie Huang1, Shengchen Jiang1, Fengqiu Ruan2
1Department of Radiology, The First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi, China.
Abstract:
BACKGROUND Portal vein tumor thrombus (PVTT) is a critical complication in hepatocellular carcinoma (HCC). Spectral computed tomography (CT) is increasingly used to enhance the diagnosis of such conditions. This study examines the effect of different iodine concentrations in contrast media on portal vein image quality and iodine intake using spectral CT to improve imaging techniques. MATERIAL AND METHODS A total of 88 patients were divided into 3 groups based on iodine concentration in contrast media: Group A (300 mgI/mL, n=30), Group B (320 mgI/mL, n=28), and Group C (350 mgI/mL, n=30). Each underwent a GSI scan with an injection rate of 4.5 mL/s and a dose of 1.5 mL/kg. Eleven sets of 40-140 keV images were reconstructed for each group. CT value, image noise, contrast noise ratio (CNR), signal-to-noise ratio (SNR), and subjective image scores of intra-hepatic and extra-hepatic portal veins were analyzed. Optimal monochromatic levels and iodine intake were assessed for each group. RESULTS The optimal monochromatic level for portal veins was between 80 keV-110 keV across groups. Significant differences were noted in CT values and image noise among groups (P<0.05), but not in CNR, SNR, or subjective scores (P>0.05). Iodine intake was reduced by 21.29% in Group A and 14.60% in Group B compared to Group C. CONCLUSIONS GSI scans with low-concentration contrast media effectively reduce iodine intake while maintaining image quality during liver CT-enhanced scans.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...

