Related Experiment Video
Updated: May 20, 2025

Force System with Vertical V-Bends: A 3D In Vitro Assessment of Elastic and Rigid Rectangular Archwires
Published on: July 24, 2018
The Effect of MRI Exposure on the Shear Bond Strength and Adhesive Remnant Index of Different Bracket Types
Luka Šimunović1, Jakov Stojanović2, Katarina Tečić2
1Department of Orthodontics, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia.
Abstract:
Background/Objectives: Magnetic resonance imaging (MRI) is widely used in diagnostics, but its effects on orthodontic materials remain a concern. This study aimed to evaluate the impact of MRI exposure at 1.5 T and 3 T on the shear bond strength (SBS) and adhesive remnant index (ARI) of different orthodontic bracket types (metal, self-ligating, and ceramic). Methods: A total of 90 extracted human premolars were divided into three groups (control, 1.5 T, and 3 T MRI exposure). The three bracket types were bonded using Transbond XT adhesive and subjected to standardized polymerization. MRI scans were conducted using 1.5 T and 3 T machines with clinically relevant sequences. SBS was measured using a universal testing machine, and the ARI was assessed under a stereomicroscope. Statistical analysis was performed using Kruskal-Wallis and chi-square tests. Results: MRI exposure influenced SBS and the ARI differently across bracket types. Firstly, 3 T MRI exposure significantly reduced SBS in self-ligating (p = 0.017) and ceramic brackets (p = 0.014) compared to the control, whereas metal brackets showed no significant changes. ARI scores varied across MRI conditions, with metal and self-ligating brackets showing increased adhesive retention at higher field strengths. No significant differences were observed in ARI scores for ceramic brackets across MRI conditions. Conclusions: The clinical importance of understanding these results is that both patients and clinicians must be aware of inevitable changes that occur in SBS during MRI, since exposure to high-field MRI, particularly 3 T, may alter bond strength and adhesive failure characteristics.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
07:09In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
Related Concept Videos
Bonding and Strength of Aggregate
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...