The Effect of MRI Exposure on the Shear Bond Strength and Adhesive Remnant Index of Different Bracket Types
Related Experiment Video
Updated: May 20, 2025

Force System with Vertical V-Bends: A 3D In Vitro Assessment of Elastic and Rigid Rectangular Archwires
Published on: July 24, 2018
Luka Šimunović1, Jakov Stojanović2, Katarina Tečić2
1Department of Orthodontics, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia.
Abstract:
Background/Objectives: Magnetic resonance imaging (MRI) is widely used in diagnostics, but its effects on orthodontic materials remain a concern. This study aimed to evaluate the impact of MRI exposure at 1.5 T and 3 T on the shear bond strength (SBS) and adhesive remnant index (ARI) of different orthodontic bracket types (metal, self-ligating, and ceramic). Methods: A total of 90 extracted human premolars were divided into three groups (control, 1.5 T, and 3 T MRI exposure). The three bracket types were bonded using Transbond XT adhesive and subjected to standardized polymerization. MRI scans were conducted using 1.5 T and 3 T machines with clinically relevant sequences. SBS was measured using a universal testing machine, and the ARI was assessed under a stereomicroscope. Statistical analysis was performed using Kruskal-Wallis and chi-square tests. Results: MRI exposure influenced SBS and the ARI differently across bracket types. Firstly, 3 T MRI exposure significantly reduced SBS in self-ligating (p = 0.017) and ceramic brackets (p = 0.014) compared to the control, whereas metal brackets showed no significant changes. ARI scores varied across MRI conditions, with metal and self-ligating brackets showing increased adhesive retention at higher field strengths. No significant differences were observed in ARI scores for ceramic brackets across MRI conditions. Conclusions: The clinical importance of understanding these results is that both patients and clinicians must be aware of inevitable changes that occur in SBS during MRI, since exposure to high-field MRI, particularly 3 T, may alter bond strength and adhesive failure characteristics.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
07:09In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
Related Concept Videos
Bonding and Strength of Aggregate
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...