Critical Review of the Methodological Shortcoming of Ambulatory Blood Pressure Monitoring and Cognitive Function
Shahab Haghayegh1,2,3, Ramon C Hermida4,5,6, Michael H Smolensky6,7
1Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, MA 02114, USA.
Abstract:
Growing evidence suggests that abnormal diurnal blood pressure rhythms may be associated with many adverse health outcomes, including increased risk of cognitive impairment and dementia. This study evaluates methodological aspects of research on bidirectional associations between ambulatory blood pressure monitoring (ABPM) patterns and cognitive function. By examining the 28 recent studies included in a recent systematic review on the association between ABPM patterns with cognitive function and risk of dementia, our review revealed several significant limitations in study design, sample characteristics, ABPM protocol, cognitive assessment, and data analysis. The major concerns include a lack of diversity in study populations with underrepresentation of Blacks and Latinos, a predominant focus on Alzheimer's disease or all-cause dementia without distinguishing other dementia subtypes, different and not standardized measures of cognition or dementia, prevalent use of 24 h monitoring without considering the adaption effect, inconsistent definitions of dipping status, and ignorance of individual differences in timings of daily activities such as bed and awakening times. In addition, confounding variables such as class, dose, and timing of antihypertensive medication are inadequately controlled or considered. Further, longitudinal studies were scarce examining the bidirectional relationship between ABPM patterns and cognitive decline over time. Collectively, these deficiencies undermine the reliability and generalizability of current findings. Addressing these methodological challenges is crucial for a more comprehensive understanding of diurnal blood pressure rhythms in diverse populations and for developing an evidence-based guideline for ambulatory monitoring and control of blood pressure across the sleep-wake cycle to prevent cognitive decline and dementia.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...