Injury pattern(s) in electric iron-related fatal electrocutions in the home

Sangram S Yadav1, Mohit Chauhan2

  • 1Department of Forensic Medicine and Toxicology, Bhagat Phool Singh Government Medical College for Women, Sonipat, India.

PubMed

Related Concept Videos

Household Wiring And Electrical Safety01:13

Household Wiring And Electrical Safety

Companies that supply power to most modern households use three conductors, typically called a three-wire line. While one is neutral, the other two are both at 120 V but with opposite polarity, giving a voltage of 240 V between them. With a three-wire line, high-power appliances that require 240 V, such as electric stoves and clothes dryers, are linked between the two hot lines. 120 V appliances can be connected between the neutral and either of the hot lines. The neutral side, which is always...
1.1K
Faraday's Law01:10

Faraday's Law

Faraday's law state that the induced emf is the negative change in the magnetic flux per unit of time. Any change in the magnetic field or change in the orientation of the area of the coil with respect to the magnetic field induces a voltage (emf). The magnetic flux measures the number of magnetic field lines through a given surface area. Magnetic flux is estimated from the integral of the dot product of the magnetic field vector and the area vector. The negative sign describes the...
3.9K
Power Distribution in Three-phase and Single Phase Circuits01:17

Power Distribution in Three-phase and Single Phase Circuits

Power distribution within electrical circuits is a foundational aspect of residential and industrial energy systems. While single-phase power is common in residential settings, three-phase power is the standard for industrial environments with heavy machinery. Each system is different and has advantages, and it's crucial to understand the underlying principles of power distribution and material efficiency.
Single-Phase Power Distribution:
Single-phase circuits are typical in household...
282
Fault Types01:18

Fault Types

When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
61
Insulation Coordination01:23

Insulation Coordination

Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
103
Eddy Currents01:25

Eddy Currents

Since eddy currents occur only in conductors, magnets can separate metals from other materials. For example, in a recycling center, trash is dumped in batches down a ramp, beneath which lies a powerful magnet. Conductors in the trash are slowed by eddy currents, while nonmetals in the trash move on, separating from the metals. This works for all metals, not just ferromagnetic ones.
Other major applications of eddy currents appear in metal detectors and the braking systems of trains and roller...
1.5K