Green solvent-based high-throughput dispersive liquid-liquid microextraction for detecting strobilurin fungicides in
Jin Liu1, Wei Pan2, Suzhen Li2
1Shanxi Key Laboratory of Integrated Pest Management in Agriculture, College of Plant Protection, Shanxi Agricultural University, Taiyuan, Shanxi 030031, China; College of Food Science and Engineering, Shanxi Agricultural University, Taigu, Shanxi 030801, China.
Abstract:
A green solvent-based high-throughput dispersive liquid-liquid microextraction (HTDLLME) method has been developed as an environmentally friendly, straightforward, and efficient sample pretreatment technique. Six batches of extractant (eucalyptol) and dispersant (γ-valerolactone) mixtures were simultaneously injected into six samples and uniformly dispersed using electric 12-channel pipettes, achieving rapid extraction. The extractant and dispersant are sustainable, renewable, and non-toxic, eliminating the need for harmful solvents. The rapid dispersion and spontaneous separation of the extractant do not require auxiliary devices or demulsifiers, aside from the electric 12-channel pipettes. The combined use of electric 12-channel pipettes and deep-well plates increased pretreatment throughput, enabled semi-automatic operation, and improved overall efficiency. UHPLC-MS/MS was selected as the detector to ensure the sensitivity of the proposed method. Under optimal extraction conditions, the linear range was 0.002-0.2 μg L-1. The limit of detection and limit of quantification were 0.001 μg L-1 and 0.002 μg L-1, respectively. The intra-day and inter-day relative standard deviations ranged from 2.4 % to 5.5 % and 1.5 % to 5.8 %, respectively. The green solvent-based HTDLLME-UHPLC-MS/MS method achieved rapid detection of SFs in different environmental samples, with extraction recoveries of 81.1 %-105.8 %. Greenness and blueness evaluation tools confirmed the environmental friendliness and practicality of the method. The green solvent-based HTDLLME approach provides a sustainable, straightforward, and practical solution for processing multiple samples simultaneously, supporting effective environmental monitoring.
More Related Videos
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
