Reducing device-related pressure injuries in high-risk neonates receiving nasal continuous positive airway pressure:
Margaret Broom1,2, Alison L Kent3,4, Tejasvi Chaudhari5,3
1Neonatal Department, Canberra Hospital, Garran, Australian Capital Territory, Australia margaret.broom@act.gov.au.
Objective:
Neonates requiring Non-InVasive respiratory Support (NIVS) are at high risk of device-related pressure injury (DRPI), with incidence rates of 20%-60% in extremely premature infants. Over a 4-year period, our team undertook a Quality Improvement Project to review aspects of the clinical management of NIVS: types of interfaces, introduction of hydrocolloid dressing and the development and implementation of nasal injury care plan (NICP) to reduce DRPI in high-risk neonates.
Design:
A prospective descriptive study was completed in three stages: trial of nCPAP interfaces, preintroduction NICP (2016-2018), post-NICP (2018-2020) and (2021-2022) to measure sustainability of implementation. Data included: gestational age (GA), birth weight, NIVS days, incidence, grade and day of DRPI. Statistical analysis of incidence rate ratio was completed between pre and postgroups.
Setting:
Australian neonatal intensive care unit.
Patients:
All neonates ≤32 weeks requiring nCPAP.
Interventions:
Evaluation of types of interfaces, introduction of hydrocolloid dressing and the development and implementation of NICPMain outcome measures: incidence and severity of DRPI.
Results:
Total DRPI recorded in all CPAP babies pre/post NICP were (59/659 (9.0%), 26/574 (4.5%), p=0.0032, respectively). Analysis showed DRPI incidence rates per 1000 NIVS days ((10.6, 5.5), p=0.0001, respectively). 75 (88%) of DRPI occurred in the ≤32 week group of neonates requiring NIVS. Review of babies ≤32 weeks across the three intervals showed significant improvement with time (55 (19%); 27 (13%); 19 (9%), p=0.0001).
Conclusions:
Preferred nCPAP interface, nasal dressing and NICP have reduced the incidence and severity of DRPI in the NICU.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Suctioning the Nasopharyngeal Airway
Equipment Required
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Epistaxis
Etiology
Possible causes of this condition include high blood pressure, trauma, low humidity, upper respiratory tract infections, allergies, foreign bodies, nasal inhalation of corticosteroids or illicit drugs, excessive use of decongestant nasal sprays, facial or nasal surgery, anatomic malformation, tumors, or systemic...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...