Related Experiment Video
Updated: May 20, 2025

Guided Endodontics: Three-Dimensional Planning and Template-Aided Preparation of Endodontic Access Cavities
Published on: May 24, 2022
Evaluation of Cone Beam Computed Tomography Resolution, 3D Printing Resolution and Drilling Depth on Drilling
Marine Hénaut1, Maarten Meire2, Jérôme Vandomme3
1Department of Restorative Dentistry and Endodontics, University of Lille, Faculty of Odontology, Inserm, CHU Lille, Lille, France.
Objective:
The aim of this study was to evaluate the influence of cone-beam computed tomography (CBCT) resolution, 3D printing resolution, and drilling depth on drilling accuracy in guided endodontic access.
Methods:
Fifty-six printed canines were designed, fabricated, and mounted in maxillary arch models. Preoperative CBCT and 3D surface scan were matched and used to design a surgical guide with different planning parameters: 1) reference (high-resolution CBCT (80 µm) and 3D printing (50 µm), shallow drilling (14 mm)), 2) low-resolution CBCT (120 µm), 3) low-resolution 3D printing (100 µm) and 4) deep drilling (high-resolution CBCT (80 µm) and 3D printing (50 µm), deep drilling (21 mm)). Guided access into the printed canines was performed in a simulated clinical setting. A postoperative CBCT was matched with the planning data in order to determine the angular and linear (total, mesiodistal, buccolingual and depth) deviation between the planned and performed cavities. Mann-Whitney test was used to analyse differences between the reference group and each test group.
Results:
Angular, total linear and buccolingual deviations were significantly higher in the low-resolution CBCT group than in the reference group (median: 3.10° and 2.0° (p<0.01), 1.41 mm and 1.06 mm (p<0.05) and 0.77 mm and 0.41 mm (p<0.05), respectively). Depth deviation was significantly higher in the low-resolution 3D printing group than in the reference group (median: 0.90 mm and 0.45 mm (p<0.01), respectively). No other significant differences between the groups were noted (p>0.05).
Conclusion:
Higher CBCT resolution resulted in lower angular and total linear deviation during guided endodontic access. Higher 3D printing resolution yielded lower vertical linear deviation. (EEJ-2024-05-086).