Background:
Proper endotracheal tube (ETT) position is crucial for neonatal lung aeration. The purpose of this study is to determine the effect of ETT tip position on lung aeration in term and preterm infants. Methods: This retrospective chart study involved neonates who were admitted to the Neonatal Intensive Care Unit (NICU) and intubated, and it was carried out from February 2023 to July 2023 at the Sindh Institute of Child Health and Neonatology. ETT tip position was analyzed, and chest x-rays (CXRs) were obtained within four hours of intubation. On a CXR, lung expansion evident to eight or eight and a half ribs was considered adequate lung inflation/aeration; fewer than eight ribs were considered poor lung inflation/aeration. To ascertain relationships between ETT tip location and lung aeration, data were examined using the chi-square test in SPSS version 26 (IBM Corp., Armonk, NY).
Results:
Out of 149 neonates, 105 (70.5%) were preterm and 44 (29.5%) were term. Optimal lung aeration was observed in 124 neonates (83.2%). The ETT tip was positioned at T1-T2 in 86 neonates (57.7%) and at T3-T4 in 63 neonates (42.3%). For term neonates, those with the ETT tip at T1-T2 exhibited significantly higher rates of optimal lung aeration (72.2%) compared to those with the tip at T3-T4 (27.8%, p = 0.019). Conversely, no significant difference in lung aeration was noted among preterm neonates based on ETT position (p = 0.745).
Conclusions:
In conclusion, our study found a significant association between ETT tip positioning at T1-T2 and optimal lung aeration in term neonates. This suggests that precise ETT placement may play an important role in achieving better lung aeration in term infants, while slight positional deviations may be less impactful for lung aeration in preterm neonates. These findings may guide NICU protocols to consider gestational age when tailoring ventilation strategies, emphasizing the importance of anatomical and physiological differences in neonatal respiratory care.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...