Related Experiment Video
Updated: Jul 13, 2026

Pre-clinical Model of Cardiac Donation after Circulatory Death
Published on: August 2, 2019
Ten hour donor heart ischemic time with 10ºC static storage
William Tucker1, Yatrik Patel1, Mark Petrovic1
1Vanderbilt University Medical Center, Department of Cardiac Surgery, Nashville, Tennessee.
Insights
Safe heart transplantation is possible with extended preservation. Utilizing 10ºC static storage for donor hearts can increase travel distances and preservation times, enabling successful transplants even from remote locations.
Area of Science:
- Cardiology
- Transplantation Surgery
- Organ Preservation
Background:
- Heart transplantation is limited by donor organ availability and preservation time.
- Extended ischemic times pose challenges for successful allograft function.
- Machine perfusion is often used to extend preservation, but static storage is simpler.
Purpose of the Study:
- To evaluate the safety and efficacy of 10ºC static storage for extending heart transplant ischemic time and travel radius.
- To assess the feasibility of long-distance heart transport using static preservation.
- To demonstrate excellent early allograft function despite extended preservation.
Main Methods:
- A heart donor organ was transported from Anchorage, AK, to a recipient center using 10ºC static storage.
- The total ischemic time exceeded 10 hours for the approximately 2,700 nautical mile journey.
- The recipient had a history of ischemic cardiomyopathy, a left ventricular assist device (LVAD), and end-stage renal disease, requiring a combined heart-kidney transplant.
Main Results:
- The donor heart was successfully transported and implanted, demonstrating superb early allograft function.
- The 10ºC static storage safely extended the ischemic time and travel radius for heart transplantation.
- Excellent outcomes were achieved without the need for machine perfusion.
Conclusions:
- Extended ischemic times and increased travel radii in heart transplantation are achievable with 10ºC static storage.
- Good recovery, storage, and implant techniques are crucial for excellent outcomes.
- Static cold storage remains a viable and effective method for donor heart preservation over long distances.
Abstract:
Utilization of 10ºC static storage safely extended both ischemic time and travel radius in heart transplantation. A 57-year-old man with ischemic cardiomyopathy, a left ventricular assist device (LVAD), and end-stage renal disease was listed for combined heart-kidney transplant. The donor hospital in Anchorage, AK, was located approximately 2,700 nautical miles and 8 hours from the recipient center. The organ was transported in 10ºC static storage with over 10 hours of ischemic time and had superb early allograft function. Excellent outcomes with extended ischemic times can be achieved without machine perfusion, provided good recovery, storage, and implant techniques are followed.