Related Experiment Video
Updated: Jun 23, 2026

Establishment of a Segmental Femoral Critical-size Defect Model in Mice Stabilized by Plate Osteosynthesis
Published on: October 12, 2016
Biomechanical insights to mitigate lateral hinge fracture risk in opening-wedge high tibial osteotomy
Haoyue Wu1, Kyung-Hwan Jung2, Xinyu Na3
1Department of Mechanical Engineering, Konkuk University, Seoul, South Korea.
Abstract:
Lateral hinge fractures (LHFs) are serious complications of high tibial osteotomy (HTO). We aimed to establish the relationship between osteotomy parameters and LHF risk factors using finite element simulation. The parameters analyzed included cutting position, hinge position, and correction angle. Optimizing the hinge position in HTO reduced stress and strain concentrations. An osteotomy with a 40 mm cutting position and an AL hinge effectively minimized force moments and stress while ensuring that strain remained below the cortical bone's yield limit. These findings highlight the importance of optimizing osteotomy parameters to reduce LHF risk and improve surgical outcomes in HTO.