The aim of the study was to investigate novel, minimally invasive cryoneurolysis for refractory or plateaued upper limb spasticity.
Design:
This was a repeated-measures, single-center, observational pilot study (NCT04670783). Percutaneous cryoneurolysis was applied to the upper limb nerves and intramuscular branches of 59 adults with upper limb spasticity refractory to or plateaued on botulinum therapies. Maximal passive range of motion (V1), active ROM, and modified Ashworth scale score were measured during shoulder flexion, abduction, and external rotation and elbow and wrist extension at baseline and follow-up to 1 yr. Additional outcomes included pain, participant satisfaction, and upper limb disability.
Results:
Overall, 59 participants received cryoneurolysis in ≥1 region targeting nerves that innervate muscles supporting shoulder ( n = 47), elbow ( n = 33), wrist ( n = 18), and fingers/thumb ( n = 29) movement. At 12 mos, there was significant change from baseline in V1, active ROM, and modified Ashworth scale score for shoulder flexion and abduction and in V1 and modified Ashworth scale score for external rotation. Similar results were observed for elbow extension V1, active ROM, and modified Ashworth scale score and wrist extension modified Ashworth scale score. Average daily pain, participant satisfaction, and upper limb disability improved.
Conclusions:
Participants with plateaued or refractory spasticity had improvements in upper limb regions; future evaluations of cryoneurolysis treatment for spasticity are warranted.
More Related Videos
Related Concept Videos
Thermosensation
Decreased Body Temperature
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...