Related Experiment Video
Updated: May 10, 2026

An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
The Role of Proximal Locking Fixation in Volar Distal Radius Fracture Fixation
Leland Gossett1, Giap H Vu2, Wayne Reizner1
1Department of Orthopaedics, University of Rochester School of Medicine and Dentistry, Rochester, New York.
Abstract:
Background Volar-locked plating has become a popular treatment option for unstable distal radius fractures. While using locking screws in the distal fragment increases the stability of the fixation, the biomechanical benefits of locking fixation in the proximal fragment have not been definitively established. Purposes This study evaluated the initial mechanical behavior of the volar plating construct with different locking screw configurations in the proximal fragment. Materials and Methods Sixteen Sawbones radius models were used. An unstable metaphyseal distal radius fracture was created and fixated with a volar-locked plate. Four different screw configurations in the proximal fragment were tested: all nonlocking screws, locking screw in the distal-most hole, locking screw in the proximal-most hole, and locking screws in both the proximal- and distal-most holes. Initial stiffness, displacement during harmonic loading, and load-to-failure were compared among the three groups. Results The initial stiffness, displacement during harmonic loading, and load-to-failure did not significantly differ among the four proximal screw configurations ( p < 0.05). Failure occurred via toggling of the screws in the configuration with all nonlocking screws and through screw breakage or locking mechanism failure in the configurations with locking screws. Conclusion The use of locking screws in the proximal fragment did not significantly affect the initial stability of volar distal radius plating. However, failure modes differed between the nonlocking and locking configurations, consistent with known mechanical properties of locking fixation. Further mechanical studies in cadaveric models and clinical trials are warranted to determine the optimal screw configuration in volar distal radius plating. Level of Evidence To be determined. Biomechanical study on synthetic models.
More Related Videos
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
11:21Development of a Novel Internal Fixation Model for Rat Radial Fractures: Fracture Healing Assessment and Dorsal Root Ganglion Isolation
Published on: March 13, 2026
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...
Bones of the Upper Limb: Ulna
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a short...