A Universal Quantitative Residual Solvent Analysis of Solids and Liquids Using a Full Evaporative Technique and
Allison Ferranti1, Taylor Hayward1
1Plasmion, GmbH, 400 Route 518, Skillman, NJ 08558, USA.
Abstract:
Residual solvent analysis is a common method used in the manufacturing of finished goods and pharmaceuticals to ensure the safety of the final product to the consumer. Typically, this involves a headspace sample introduction set up and then separation by gas chromatography (GC) with detection by a flame ionization detector (FID). This analysis can be very time consuming in sample preparation, calibration and analysis time. A full evaporative technique has been applied to both solid and liquid samples for the rapid vaporization of the solvent analytes, which is then introduced to a GC for separation. Additionally, a methanizer was used in line with the FID creating a uniform response for solvents of various heteroatoms and functionalities. This combination of full evaporative technique with a methanized-FID allows for the use of a single response factor for residual solvent analysis with demonstrated repeatability of ˂4%RSD. Spiked solid sample analysis shows recovery between 95% and 105% of solvents tested at ⁓2 μg of each analyte. Overall, the combination of full evaporative headspace sampling and methanized-FID can be applied to any sample matrix for any solvent used in manufacturing or production, making a universal method for residual solvent analysis.
Related Concept Videos
Volatilization
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Gas Chromatography: Types of Detectors-II
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...