Non-invasive and continuous intra-abdominal pressure assessment using MC sensors
Boštjan Plešnik1,2, Mihajlo Djokić3,4, Srdjan Djordjević5
1University Medical Centre Ljubljana, Zaloška cesta 7, Ljubljana, Slovenia. bostjan.plesnik@gmail.com.
A novel muscle contraction sensor accurately monitors intra-abdominal pressure (IAP), aiding in early detection of intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) in critical care patients.
Area of Science:
- Critical care medicine
- Medical device technology
- Surgical monitoring
Background:
- Intra-abdominal pressure (IAP) monitoring is vital for preventing severe complications like intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS).
- Existing methods for IAP measurement can be invasive or lack continuous monitoring capabilities.
Purpose of the Study:
- To evaluate the accuracy and reproducibility of a novel, non-invasive muscle contraction (MC) sensor for monitoring IAP.
- To assess the correlation between MC sensor readings and objective IAP measurements obtained via CO2 insufflation.
Main Methods:
- 41 patients undergoing laparoscopic cholecystectomy were enrolled.
- Two MC sensors were applied abdominally, and IAP was incrementally increased using CO2 insufflation.
- MC sensor readings were compared against randomized IAP values from the CO2 insufflator.
Main Results:
- The MC sensor demonstrated continuous and accurate IAP detection.
- A strong positive linear correlation (Pearson's r = 0.963, R² = 0.927) was found between MC sensor and insufflator measurements.
- The MC system showed high accuracy in identifying IAH (AUC = 0.996) and ACS (AUC = 0.981).
Conclusions:
- The transcutaneous MC sensor is an accurate, non-invasive method for IAP assessment, correlating strongly with CO2 insufflation measurements.
- This innovative device offers a potential alternative to conventional IAP monitoring methods.
- Real-time data from MC sensors can facilitate proactive patient care and early intervention for critical conditions.
More Related Videos
04:34A Novel Non-invasive Method for the Detection of Elevated Intra-compartmental Pressures of the Leg
Published on: May 31, 2019
09:56Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure