A method to determine confidence limits for the area, sedimentation coefficient, and molar mass of individual peaks

John S Philo1

  • 1Alliance Protein Laboratories, San Diego, CA, USA. jphilo@mailway.com.

PubMed

Related Concept Videos

Confidence Intervals01:21

Confidence Intervals

An unbiased point estimate is often insufficient to predict a population estimate, such as population mean or population proportion. In this scenario, a confidence interval is used. A confidence interval is an estimate similar to a sample proportion. However, unlike the point estimate which is a single value, the confidence interval contains a range of values. These values have lower and upper limits, known as confidence limits, and can be designated as L1 and L2, respectively.
A confidence...
Confidence Coefficient01:24

Confidence Coefficient

The confidence coefficient is also known as the confidence level or degree of confidence. It is the percent expression for the probability, 1-α, that the confidence interval contains the true population parameter assuming that the confidence interval is obtained after sufficient unbiased sampling; for example, if the CL = 90%, then in 90 out of 100 samples the interval estimate will enclose the true population parameter. Here α is the area under the curve, distributed equally under both the...
Mass Spectrum: Interpretation01:24

Mass Spectrum: Interpretation

An unknown compound can be established by identifying the molecular ion peak in the mass spectrum. The molecular ion peak is often weak or absent due to the predominance of fragmentation in high-energy electron beams. In such cases, a soft-energy electron beam can be used to scan the spectrum to enhance the intensity of the molecular ion peak. Additionally, chemical ionization, field ionization, and desorption ionization spectra are used to obtain a relatively intense molecular ion peak.To...
Contaminants and Errors01:16

Contaminants and Errors

Effective sample preparation is crucial for accurate and reliable laboratory analysis. During this process, two significant sources of error can arise: concentration bias from improper sample splitting and contamination caused by methods used to reduce particle size, such as grinding or homogenization. Identifying and minimizing these potential errors is crucial to ensuring the validity of the analysis.
Another key consideration is determining the appropriate number of samples required to...
Size-Exclusion Chromatography01:08

Size-Exclusion Chromatography

In size-exclusion chromatography (SEC), also known as molecular-exclusion or gel-permeation chromatography, molecules are separated based on their sizes. This technique is important for separating large molecules such as polymers and biomolecules. The two classes of micron-sized stationary phases encountered in SEC are silica particles and cross-linked polymer resin beads. Both materials are porous, but their pore sizes vary significantly.
Silica particles offer advantages such as rigidity,...
Capillary Electrophoresis: Applications01:30

Capillary Electrophoresis: Applications

Capillary electrophoretic separations offer various modes, each with unique applications. These modes include capillary zone electrophoresis, capillary gel electrophoresis, capillary array electrophoresis, capillary isoelectric focusing, capillary isotachophoresis, micellar electrokinetic chromatography, and capillary electrochromatography.
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...