A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients
Published on: October 17, 2017
Intracranial pressure and pulsatility in different head and body positions
Matthew J Bancroft1,2, Eleanor M Moncur1,3, Amy L Peters2
1Department of Brain Repair & Rehabilitation, UCL Queen Square Institute of Neurology, London WC1N 3BG, UK.
Abstract:
Intracranial pressure (ICP) is typically measured with the head in a neutral position whilst the body is in an upright or supine posture. The effect of body position on ICP is well studied, with ICP greater when supine than when upright. In daily life the head is frequently moved away from the neutral position but how this impacts ICP dynamics is unclear. Knowledge of ICP dynamics in different head-on-body positions may improve future treatments that restore normal ICP dynamics such as CSF drainage shunts. We recruited 57 relatively well, ambulatory patients undergoing clinical ICP monitoring for investigation of possible CSF dynamics disturbances to a single-centre, cross-sectional study. Forty-one patients were non-shunted, seven had a working shunt and nine had a malfunctioning shunt. We measured ICP and ICP pulsatility (pulse amplitude) over 10 or 20 s in different combinations of head and body positions. Positions included right and left head turn and forward tilt in upright (seated, standing) and supine body positions, and right and left lateral tilt and backward tilt in upright body positions. ICP increased by 3-9 mmHg, on average, when the head moved away from neutral to each head position in upright and supine body positions, except for head forward tilt when supine, where ICP did not change. The increase in ICP with head turn and forward tilt in upright body positions was larger in patients with a malfunctioning shunt than with no shunt or a functioning shunt. Pulsatility also increased by 0.5-2 mmHg on average when the head moved away from neutral to each head position in upright and supine body positions, except for head forward tilt in upright body positions where pulsatility slightly decreased by 0.7 mmHg on average. ICP and pulsatility generally increase when the head is moved away from the neutral position, but this depends on a combination of head and body position and shunt status. We propose our results can be explained by a combination of changes to neck vasculature and head orientation relative to gravity. Our findings provide potential reason for patient reports that ICP-related symptoms can be induced and/or exacerbated by head movement and could explain behaviours that avoid excess head movement, such as turning the body rather than the head when looking to the side. Our data describe the predicted change in ICP in different head and body positions and could underpin future smart shunt design.
Related Concept Videos
Measurement of Blood Pressure
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Blood Pressure
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...