Related Experiment Video
Updated: May 17, 2025

Author Spotlight: Integrating Computational and Experimental Approaches in Precision Oncology
Published on: December 1, 2023
CFD-DEM coupling analysis of the negative pressure inlet structural parameters on the performance of integrated
Dandan Han1, Wei Li1, Yunxia Wang2
1College of Mechanical and Electrical Engineering, Sichuan Agricultural University, Ya'an, China.
Abstract:
To assess the influence of the structural parameters of the negative pressure inlet pipe on the seeding performance of the integrated positive-negative pressure seed-metering device, angles α and β, along with taper θ, were selected as test variables for conducting coupling simulation tests and physical bench tests. The results indicate that the average differential pressure across the holes in the seed-filling zone (Δp ), the airflow rate at the interaction interface between the negative pressure inlet pipe and the negative pressure chamber (Q), the average drag force on seeds in the seed-filling zone (F D, ), and the average drag force on seeds in the seed-cleaning zone (F D, ) are all significantly affected by the test factors. The structural parameters of the negative pressure inlet pipe can be accurately predicted using the prediction model developed through regression analysis of the central composite test results. The optimal parameters combination is established as 17.1° for angle α, 81.3° for angle β, and 0.52° for taper θ. The maximum error between the predicted evaluation index values and those obtained from the coupling simulation verification test with the optimized negative pressure inlet pipe is less than 6.66%, indicating a strong correlation and reasonable prediction of the structural parameters. The results from the physical bench tests confirm that the optimal operational speed for the seed-metering device with the optimized negative pressure inlet pipe is 4 to 5 km/h, with an optimal working negative pressure of 4 to 6 kPa. Under these conditions, the qualified rate varies from 92.27% to 95.28%, the multiple rate from 2.43% to 5.52%, and the leakage rate from 1.22% to 5.2%.
More Related Videos
09:04A Modeling and Simulation Method for Preliminary Design of an Electro-Variable Displacement Pump
Published on: June 1, 2022
13:27Exploring the Effects of Atmospheric Forcings on Evaporation: Experimental Integration of the Atmospheric Boundary Layer and Shallow Subsurface
Published on: June 8, 2015
Related Concept Videos
Pipe Flowrate Measurement: Problem Solving
Dimensional Analysis
In fluid mechanics, dimensional...
Pipe Flowrate Measurement
The orifice meter is a simple,...
Application of the Linear Momentum Equation
The goal is to determine the force components in the x and y directions to hold the pipe in place. Since...
Design Example: Forces in Sluice Gate
Key variables in...
Free Jet